ML17173A456

From kanterella
Jump to navigation Jump to search
Forwards LER#78-064/03L-0
Date released: 02/10/2020 Download: ML17173A456


LER#78-064/03L-0 on 781124:leak Found in 6x6x4 Eductor on the 2/3 Waste Collector Tank Recirculation Line.Caused by Acid Corrosion of Carbon Steel Side of Weld;Carbon Steel Flange Will Be Replaced W/Flange of Stainless Steel
ML20027A578
Person / Time
Site: Dresden 
Issue date: 12/21/1978
From: Jansen T
COMMONWEALTH EDISON CO.
To:
References
Download: ML20027A578 (1)
Forwards LER#78-064/03L-0
ML17173A453
Person / Time
Site: Dresden 
Issue date: 12/21/1978
From: Stephenson B
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17173A453 (3)