Forwards LER#78-033/03X-1
Date released: 02/10/2020 Download: ML17173A451


LER#78-033/03X-1 on 780522:during Test Performed on U-2 D/G to Measure Overshoot & Overspeed Setpoint,The Diesel Tripped 4 Times Due to Overspeed Caused by Governor Speed Set Too High
ML20027A563
Person / Time
Site: Dresden 
Issue date: 12/12/1978
From: Chan J
COMMONWEALTH EDISON CO.
To:
References
Download: ML20027A563 (2)
Forwards LER#78-033/03X-1
ML17173A450
Person / Time
Site: Dresden 
Issue date: 12/12/1978
From: Stephenson B
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17173A450 (3)