Text

CATEGORY 2

REGULATORY INFORMATION DISTRZBUTXON SYSTEM

(RZDS)

SSXON NBR:9904290222

DOC.DATE: 99/04/19

NOTARIZED: NO

CIL:50-387 Susquehanna

Steam Electric Station, Unit 1, Pennsylva

50-388

Susquehanna

Steam Electric Station, Unit 2, Pennsylva

AUTH.NAME

AUTHOR AFFILIATION

COWGILL,C.J.

Region

1 (Post

820201)

RECXP.NAME

RECIPIENT AFFILIATION

BYRAM,R. G.

Pennsylvania

Power

6 Light Co.

SUBJECT: Forwards insp repts

50-387/99-03

E 50-388/99-03

on 990202-

~ 0315.Violations identified involving core. spray sys

surveillance tests

8 radiation monitors on residual heat

removal

SWS being treated

as non-cited violations.

DISTRIBOTION CODE: IEOIP

COPIES

RECEIVED:LTR'

ENCL

I

SIZE:

TITLE: General,(50

Dkt)-Insp Rept/Notice of Violation Response

NOTES:

DOCKET

05000387

05000388

E

05000387

0

INTERNAL:

RECIP IENT

ID CODE/NAME

LPD1-1 PD

ACRS

DEDRO

NRR/DIPM/IOLB

NUDOCS-ABSTRACT

OGC/HDS2

COPIES

LTTR ENCL

1

1

2

2

1

1

'

1

1

1

1

1

RECZPZENT

ID CODE/NAME

NERSES,V

AEOD

NRR/DRXP/REXB

OE

RGN1

FILE

01

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1.

1

1

2

EXTERNAL, LMITCO MARSHALL

NRC PDR

1

1

1

1

NOAC

NUDOCS FULLTEXT

1

1

1

1

NOTES:

'1

1

LOAGF.D FROM

FLF.QTRQNC RK

N

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM'DISTRIBUTION LISTS

OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL

DESK

(DCD)

ON EXTENSION 415-2083

TOTAL NUMBER OF COPIES

REQUIRED: LTTR

18

ENCL

18

Ie

April 19, 1999

Mr. Robert G. Byram

Senior Vice President - Nuclear

PP&L, Inc.

2'North Ninth Street

Allentown, Pennsylvania

18101

SUBJECT:

NRC INTEGRATED INSPECTION REPORT 50-387/99-03 and 50-388/99-03

Dear Mr. Byram:

On March 15, 1999, the NRC completed an inspection at your Susquehanna

Steam Electric

Station (SSES) Unit 18 2 reactor facilities. The inspections covered routine activities by the

resident inspectors a'nd an announced inspection of the independent spent fuel storage facility

by a Region I inspector.

The enclosed report presents the results ofthese inspections.

The

inspectors discussed the findings ofthese inspections with Mr. R. Saunders, Vice President

Nuclear Operations, Mr. G. Kuczynski, General Manager SSES, and others of your staff, at an

exit meeting at the completion of the inspection period.

During the 6-week period of inspection, your staff's conduct of activities was characterized by

~

~

~

safe operation.

We willcontinue to evaluate your staff's response to the unexpected failure of

the Unit 1 "B" residual heat removal injection valve.

Based on the results ofthis inspection, the NRC has determined that 2 violations of NRC

requirements occurred.

These violations are being treated as Non-Cited Violations (NCVs),

consistent with Appendix C of the Enforcement Policy. These NCVs are described in the

subject inspection report and involve core spray system surveillance tests and radiation

monitors on the residual heat removal service water system.

Ifyou contest the violations or

severity level ofthese NCVs, you should provide a response within 30 days of the date of this

inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington DC 20555-0001, with copies to the Regional

Administrator, Region I, and the Director, Office of Enforcement, United States Nuclear

Regulatory Commission, Washington, DC 20555-0001.

9904290222 9904i9

PDR

ADOCK 05000387

8

PDR

0

Mr. Robert G. Byram

2

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter, its

enclosure(s),

and your response will be placed in the NRC Public Document Room.

Sincerely,

ORIGINALSIGNED BY:

Curtis J. Cowgill, Chief

Reactor Projects Branch 4

Division of Reactor Projects

Docket Nos: 50-387;50-388, 72-28

License Nos: NPF-14, NPF-22

Enclosure:

Inspection Report 50-387/99-03, 50-388/99-03

cc w/encl:

R. F. Saunders, Vice President - Site Operations

G. T. Jones, Vice President - Engineering and Support

G. Kuczynski, General Manager - SSES

. T. Harpster, Supervisor, Nuclear Licensing

G. D.'Miller, General Manager - Nuclear Engineering

R. R. Wehry, Nuclear Licensing

P. Nederostek, Nuclear Services Manager, General Electric

W. H. Lowthert, Manager - Nuclear Plant Services

.

A. Male, Manager, Nuclear Assessment Services

H. D. Woodeshick, Special Assistant to the President

R. W. Osburne, Vice President, Supply & Engineering

Commonwealth of Pennsylvania

0

Mr. Robert G. Byram

Distribution w/encl:

Region

I Docket Room (with concurrences)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

PUBLIC

H. Miller, RA/J. Wiggins, DRA

C. Cowgill, DRP

D. Florek, DRP

D. Cullison, DRP

C. O'Daniell, DRP

Distribution w/encl: (Via E-Mail)

M. Tschiltz, OEDO

E. Adensam, PDI, NRR

E. Brach, NMSS/SFPO

S. Shankman, NMSS/SFPO

P. Eng, NMSS/SFPO

E. Loeds, NMSS/SFPO

M. Ross-Lee, NMSS/SFPO

V. Nerses, PM, NRR

R. Correia, NRR

DOCDESK

Inspection Program Branch, NRR (IPAS)

DOCUMENT NAME: G:'tBRANCH4tSUS9903 k.WPD

To receive a co

document,indlcatelnthebox:

'C'~Co

withoutattachment/enclosure

'E'=Co

vrithattachment/enclosure

'N'=Noco

/

9

DATE

OFFICE

R

NAME

S

e

RI/DRP

CCow ill

04/

/99

04/ /99

OFFICIALRECORD COPY

04/ /99

04/

/99