January 7, 1992 Docket Nos.

50-387 and 50-388 Hr. Harold W. Keiser Senior Vice President-Nuclear Pennsylvania Power and Light Company 2 North Ninth Street Allentown, Pennsylvania 18101 1'ear Hr. Keiser:

SUBJECT:

RE(VEST FOR ADDITIONAL INFORHATION ON PENNSYLVANIA POWER AND LIGHT COHPANY'S (PP&L) TOPICAL REPORT, PL-NF-89-005, SUSQUEHANNA STEAN ELECTRIC STATION, UNITS 1

AND 2 (TAC NOS.

H82371 AND H82372, FORHERLY TAC NOS.

75999 AND 76000)

Based on a telecommunication with PP&L held on December 10, 1991, the staff has developed an additional concern with regard to the information which PPEL has agreed to submit by January 31, 1992.

This additional concern has generated comments and questions by the staff which form the basis of this request for additional information.

These comments and questions are provided in the enclosure.

If there are any questions regarding this letter, please contact me on (301) 504-1447.

This requirement affects fewer than 10 respondents, and therefore, is not subject to Office of Hanagement and Budget review under P.L.96-511.

Enclosure:

Request for Additional Information Sincerely,

/s/

James J. Raleigh, Project Hanager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc w/

Enclosure:

See next page

.DISTRIBUTION:

'Docket File

/

NRC

& Local PDRs PDI-2 Reading SVarga JCalvo CHiller

-2 A

HO'Brien(2)

JRaleigh OGC RJones ACRS(10)

RBlough, RGN-I

-2 ac>

tc:

> er:

JWhite, RGN-I

/92: // / 92:~/779K:

r 920i i30022 -920i07 PDR AOOCK<<'05000387 P

PDR gyp HQ QEKfE CN'V

~S SEOUL C

O I/I gO

++**+

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 January 7,

1992 Docket Nos.

50-387 and 50-388 Hr. Harold W. Keiser Senior Vice President-Nuclear Pennsylvania Power and Light Company 2 North Ninth Street Allentown, Pennsylvania 18101

Dear Hr. Keiser:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION ON PENNSYLVANIA POWER AND LIGHT COMPANY'S (PP8LL) TOPICAL REPORT, PL-NF-89-005, SUSQUEHANNA STEAN ELECTRIC STATION, UNITS 1

AND 2 (TAC NOS.

H82371 AND H82372, FORMERLY TAC NOS.

75999 AND 76000)

Based on a telecommunication with PPSL held on December 10, 1991, the staff has developed an additional concern with regard to the information which PPS,L-has agreed to submit by January 31, 1992.

This additional concern has generated comments and questions by the staff which form the basis of this request for additional information.

These comments and questions are provided in the enclosure.

If there are any questions regarding this letter, please contact me on (301) 504-1447.

This requirement affects fewer than 10 respondents, and therefore, is not subject to Office of Management and Budget review under P.L.96-511.

Sincerely,

Enclosure:

Request for Additional Information cc w/

Enclosure:

See next page James J. Raleigh, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

~

~

t Mr. Harold W. Keiser Pennsylvania Power 5 Light Company Susquehanna Steam Electric Station Units 1 5 2 CC:

Jay Silberg, Esq.

Shaw, Pittman, Potts 5 Trowbridge 2300 N Street N.W.

Washington, D.C.

20037 Bryan A. Snapp, Esq.

Assistant Corporate Counsel Pennsylvania Power 5 Light Company 2 North Ninth Street Al1 entown, Pennsylvani a 18101 Mr. J.

M. Kenny Licensing Group Supervisor Pennsylvania Power 5 Light Company 2 North Ninth Street Al1 entown, Pennsy 1vani a 18101 Mr. Scott Barber Senior Resident Inspector U. S. Nuclear Regulatory Commission P.O.

Box 35 Berwick, Pennsylvania 18603-0035 Mr. Thomas M. Gerusky, Director Bureau of Radiaf;ion Protection Resources Commonwealth of Pennsylvania P. 0.

Box 2063 Harri sburg, Pennsylvania 17120 Mr. Jesse C. Tilton, III Allegheny Elec. Cooperative, Inc.

212 Locust Street P.O.

Box 1266 Harrisburg, Pennsylvania 17108-1266 Mr. S. B. Ungerer Joint Generation Projects Department Atlantic Electric P.O.

Box 1500 1199 Black Horse Pike Pleasantville, New Jersey 08232 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Mr. Harold G. Stanley Superintendent of Plant Susquehanna Steam Electric Station Pennsylvania Power and Light, Company 2 North Ninth Street Allentown, Pennsylvania 18101 Mr. Herbert D. Woodeshick Special Office of the President Pennsylvania Power and Light Company 1009 Fowles Avenue Berwick, Pennsylvania 18603 Mr. Robert G. Byram Vice President-Nuclear Operations Pennsylvania Power and Light Company 2 North Ninth Street Allentown, Pennsy1 vani a 18101

ENCLOSURE RE VEST FOR AODITIONAL INFORMATION FOR THE REVIEW F

TOPIC LLI9-DOS It is understood that PPSL has performed two different delta-CPR calculations and that the transient initial conditions were based on two different steady-state power histories and two corresponding axial power shapes, one peaking at the bottom and the second peaking at the top of the fuel rod.

NRC generally requires that bounding power histories with uncertainties be included in the determination of power'istories.

Please explain how the two steady-state power histories were determined for each of the delta-CPR calculations and how they are compatible with NRC's requirement of bounding power histories.

Also, discuss any other differences in how h

was determined for the two steady-state calculations.