Docket Nos.

50-387

,50-388 SEP 10 398)

Mr. Harold W. Keiser Senior Vice President - Nuclear Pennsylvania Power

& Light Company 2 North Ninth Street Allentown, Pennsylvania 18101

Dear Mr. Keiser:

SUBJECT:

PROGRESS STATUS OF REGION I ENGINEERING SYMPOSIUM NRC ACTION ITEMS Our letter of April 17, 1991 to the licensees and our memorandum of April 18, 1991 to the NRC attendees forwarded the meeting report of our Symposium/Workshop held oa February 20-21, 1991.

It included recommendations from the work groups for both industry and NRC.

The status and schedule for each of the recommendations to the NRC are described below.

1.

Establish consistent uidance on o erabilit and re ortabilit The Technical Specifications Branch (OTSB) is close'o completing an update to the NRC Inspection Manual on the subject of operability.

This guidance will also be sent to the industry in a generic letter (GL) that is expected to be issued shortly.

The Office for Analysis and Evaluation of Operational Data (AEOD) has formed a task group to revise NUREG-1022, "Licensee Event Reporting Systems."

NUREG-1022 currently provides guidance for reportabi lity only under 10 CFR 50.73.

The revision will be expanded to also provide guidance for reportabi lity under 10 CFR 50.72.

AEOD expects to issue the draft revision for public comment in the near future.

2.

Endorse NSAC-125 for 10 CFR 59.59 reviews

Recently, both the industry and the staff sent NUMARC comments on NSAC-125.

NUMARC is reviewing these comments for a future revision to NSAC-125 'hen this revision is completed and reviewed, the NRC staff will provide its assessment of the NSAC-125 guidelines.

OFFICIAL RECORD COPY SYMPOSIUM NRC A/IS 0028.0.0 09/05/91 9109200149 9109i0 PDR ADOCV~ 05000387 P

PDR

Harold W. Kei ser 3.

Endorse the industr standard for desi n basis when develo ed The'staff has already completed this action item.

The November'9,

1990, memorandum from William T. Russell to the Deputy Regional Administrators regarding NUMARC's Design Basis Program Guidelines noted no inconsistencies with existing NRC positions.

The staff has no plans to issue a more formal endorsement of these guidelines.

4.

Endorse the industr uideline for timeliness for o erabilit determination when established This action item is contingent upon the development of guidelines by the industry.

The GL on operability should address this issue in a way that meets the staff's needs, and hopefully, the industry's needs as well.

5.:-

Endorse the industr definition of modification cate pries when established This action item is contingent upon the industry defining categories of modifications When this has been

done, the NRC will determine if it is appropriate to endorse the definitions.

6.

Train NRC, ersonnel in the modification rocess and o erabi lit /re ortabilit determinations When the revision to NUREG-1022 is completed, AEOD plans to conduct training on the new reportabi lity guidance.

Some workshops have already been held in the Regions on this subject.

Regarding operability, OTSB plans to conduct workshops both at NRR and in the Regions to train the staff on the operability guidance going into the inspection manual and the GL.

The workshops will begin once the GL is finalized and will probably take several months to complete.

We have received many positive comments on the symposium and I attribute the success to the open discussions at the sessions.

Sincerely, Wayne Lanning, Deputy Division Director Division of Reactor Safety, RI OFFICIAL RECORD COPY SYMPOSIUM NRC A/IS " 0029.0.0 09/05/91

Harold W. Keiser cc w/encl:

A. R. Sabol,

Manager, Nuclear guality Assurance J:

M. Kenny,-Licensing Group Supervisor H. C. Stanley, Superintendent of Plant-SSES R.

G. Bryam, Superintendent of Plant-SSES S.

B. Ungerer, Manager, Joint Generation Projects Department J.

D. Decker, Nuclear Services

Manager, General Electric Co.

B. A. Snapp, Esquire, Assistant'Corporate Counsel H.

D. Woodeshick, Special Assistant to the President J.

C. Tilton, III, Allegheny Electric Cooperative, Inc.

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector Commonwealth of Pennsylvania bcc w/encl:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o encl)

J. Joyner, DRSS J. White, DRP RE Blough, DRP P.

Kaufman, DRP S. Black, EDO P. Cortland, NRR

+'~(< c RI:DRS Gregg 3J'~ j9i 08/

/91 jgP Q Pf:I:

RI:DRS Eapen

+)<>b) 08/

/91 R

RS RI:D S Du Hodges 08

/91 0 /l~/91 OFFICIAI RECORD COPY SYMPOSIUM NRC A/IS - 0030.0.0 09/05/91

e