ML17157A288

From kanterella
Jump to navigation Jump to search

Advises That 900427 Request for Approval to Use ASME Code Cases 1516-1 & 1567 Re Welding of Seats in Valves & Testing Lots of Carbon low-alloy Steel Covered Electrodes, Acceptable.Safety Evaluation Encl
ML17157A288
Person / Time
Site: Susquehanna  
Issue date: 08/21/1990
From: Butler W
Office of Nuclear Reactor Regulation
To: Keiser H
PENNSYLVANIA POWER & LIGHT CO.
Shared Package
ML17157A289 List:
References
TAC-76812, NUDOCS 9008240181
Download: ML17157A288 (5)


Text

I 'r.~

~

,Docket No. 50-387 August 21, Mr. Harold W. Keiser Senior Vice President-Nuclear Pennsylvania Power and Light Company 2 North Ninth Street Allentown, Pennsylvania 18101

Dear Mr. Keiser:

SUBJECT:

APPROVAL OF ASME CODES 1516-1 AND ELECTRIC STATION, UNIT 1 (TAC NO.

OGC PSwetland EJordan CYCheng TMcLellan 1990 DISTRIBUTION NRC PDR LPDR PDI-2 Rdg.

SVarga BBoger WButler RB1 ough MThadani ACRS (10)

JStone MO'Brien Rita Jacques,ARM/LFMB

1567, SUSQUEHANNA STEAM 76812)

We have completed our review of your request dated April 27, 1990 for approval to use ASME Code Case 1516-1, "Melding of Seats in Valves for Section III Applications,"

and Code Case 1567, "Testing Lots of Carbon and Low-Alloy Steel Covered Electrodes" for modifications during the fifth refueling outage of Susquehanna Steam Electric Station, Unit 1, scheduled in September 1990.

Based on our review, we have concluded that your use of Code Cases 1516-1 and 1567 is acceptable.

Accordingly, your request of April 27, 1990 is approved.

The bases for our conclusions are contained in the enclosed Safety Evaluation.

S incerely,

/s/

Enclosure:

Safety Evaluation cc w/enclosure:

See next page Walter R. Butler, Director Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation 76812 (doc name)

P ggpio I- /PM MThadani 1 /7 4/90 PDI-2/D MButler

// </90 OGC gg$ rh/9 (o

900$ 2401$ l 900821 RDR

'ADOCK 05000387 P "

PDC

~"

I t'

Docket No. 50-387 0

UNITED STATES NUCLEAR R EG ULATORY COMMISSION WASHINGTON, D. C. 20555 August 21, 1990 Mr. Harold W. Keiser Senior Vice President-Nuclear Pennsylvania Power and Light Company 2 North Ninth Street Allentown, Pennsylvania 18101

Dear Mr. Keiser:

SUBJECT:

APPROVAL OF ASME CODES 1516-1 AND 1567, SUSQUEHANNA STEAM ELECTRIC STATION, UNIT 1 (TAC NO. 76812)

We have completed our review of your request dated April 27, 1990 for approval to use ASME Code Case 1516-1, "Welding of Seats in Valves for Section III Applications,"

and Code Case 1567, "Testing Lots of Carbon and Low-Alloy Steel Covered Electrodes" for modifications during the fifth refueling outage of Susquehanna Steam Electric Station, Unit 1, scheduled in September 1990.

Based on our review, we have concluded that your use of Code Cases 1516-1 and 1567 is acceptable.

Accordingly, your request of April 27, 1990 is approved.

The bases for our conclusions are contained in the enclosed Safety Evaluation.

Sincerely,

Enclosure:

Safety Evaluation cc w/enclosure:

See next page Walter R. Butler, Director Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

0

Mr. Harold W. Keiser Pennsylvania Power

& Light Company Susquehanna Steam Electric Station Units I 5 2 CC:

Jay Silberg, Esq.

Shaw, Pittman, Potts 5 Trowbridge 2300 N Street N.W.

Washington, D.C.

20037 Bryan A. Snapp, Esq.

Assistant Corporate Counsel Pennsylvania Power 5 Light Company 2 North Ninth Street Al 1 entown, Pennsylvania 18101 Mr. J.

M. Kenny Licensing Group Supervisor Pennsylvania Power 5 Light Company 2 North Ninth Street Al1entown, Pennsylvania 18101 Mr. Scott Barber Senior Resident Inspector U. S. Nuclear Regulatory Commission P.O.

Box 35 Berwick, Pennsylvania 18603-0035 Mr. Thomas M. Geru s ky, Director Bureau of Radiation Protection Resources Commonwealth of Pennsylvania P. 0.

Box 2063 Harri sburg, Pennsylvania 17120 Mr. Jesse C. Tilton, III Allegheny Elec. Cooperative, Inc.

212 Locust Street P.O.

Box 1266 Harrisburg, Pennsylvania 17108-1266 Mr. S.

B. Ungerer Joint Generation Projects Department Atlantic Electric P.O.

Box 1500 1199 Black Horse Pike Pleasantvi lie, New Jersey 08232 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Mr. Harold G. Stanley Superintendent of Plant Susquehanna Steam Electric Station Pennsylvania Power and Light Company 2 North Ninth Street A 1 1 entown, Pennsylvania 18101 Mr. Herbert D. Woodeshick Special Office of the President Pennsylvania Power and Light Company 1009 Fowles Avenue Berwick, Pennsylvania 18603 Mr. Robert G. Byram Vice President-Nuclear Operations Pennsylvania Power and Light Company 2 North Ninth Street Al1entown, Pennsylvania 18101