Docket Nos.:
50-387 and 50-388 JUL 2 2 lpga DISTRIBUTION; Document Control (50-387/388)
NRC PDR L
LB82 Rdg.
MRushbr ook RPerch
- Attorney, OELD OIE Nr.
Norman M. Curtis Vice President Engineering and Construction-Nuclear Pennsylvania Power
& Light Company 2 North Ninth Street Allentown, Pennsyl vania 18101
Dear tlr. Curtis:
Subject:
Emergency Diesel Engine Air Starting System Technical Specifications To facilitate the staff review of the requirements specified in Susquehanna, Unit 1 Technical Specification 4.8. 1.1.2.d.12 regarding the emergency diesel engine air starting system, it is requested that information be provide,":to address the items listed in Enclosure (1). If you have any questions
<1n-cerning this matter, please contact R. Perch, NRC Project tlanager.
Sincerely,
Enclosure:
As stated
'Original SiyaeIi ByS Mster L. Kintner,
~
~
~
~
~
B. J. Youngblood, Chief Licensing Branch No.
1 Divis'ion of Licensing cc w/encl.:
See next page 8208i802i9 820722 PDR ADOCK 05000387 P
PDR OFFICEI SURNAME$
DATEf DL:LB/f2 RPerch(.l g......
7/21/82 DL:
Bg...Q.p.g.
7/
82 NRC FORM 318 (10-80) NRCM 0240 0 FF ICIAL R EGO R D COPY'SQ PO. 1981~960
ty Q ~l
~ C1$
~cg pg P l'
Suscuehanna Mr."Norman W. Curtis "Vice President Engineering and Construction Pennsylvania Power 8 Light Company Allentown, Pennsyl vania 18101 ccs Jay Silberg, Esquire Shaw, Pittman, Potts 5 Trowbridge 1800 M Street, N.
W.
Washington, D. C. 20036 Edward M. Nagel, Esquire General Couns'el and Secretary Pennsylvania Power 5 Light Company 2 North Ninth Street Allentown, Pennsylvania 18101 Mr. William E. Barberich Nuclear Licensing Group Supervisor Pennsylvania Power 8 Light Company 2 North Ninth Street Allentown, Pennsylvania 18101
. Mr; G.
Rhodes Resident Inspector P. 0. Box 52 Shickshinny, Pennsylvania 18655 Gerald R. Schultz, Esquire Susquehanna Envi ronmental Advocates P. 0. Box.1.560 Wilkes-Barre, Pennsylvania 18703 Mr. E. B. Poser Project Engineer Bechtel Power Corporation P. 0.
Box 3965 San Francisco, California 94119 Ms. Colleen Marsh P. 0.
Box 538A, RD 84 Mountain Top, Pennsylvania 18707 Mr. Thomas J. Halligan Correspondent The Citizens Against Nuclear Dangers P. 0. Box 5
- Scranton, Pennsyl vania 18501 Mr. J. W. Millard Project Manager Mail Code 395 General Electric Company 175 Curtner Avenue San Jose, California 95125 Robert W. Adler, Esquire Office of Attorney General 505 Executive House P. 0. Box 2357 Harrisburg, Pennsylvania 17120 Dr. J u dith H. J ohns rud Co-Director Environmental Coalition on Nuclear Power 433 Orlando Avenue State College, Pennsyl vania 16801 Mr. Thomas M. Gerusky, Director Bureau of Radiation Protection Resources Commonwealth of Pennsylvania P. 0.
Box 2063 Harri sburg; Pennsyl vania 17120
Informational Request for Emergency Diesel Engine Air Starting System 1.
Provide a copy of the test procedure used to conduct the diesel start test per the requirement of Technical Specification 4.8.1.1.2.d.12.
2.
Provide a description of the diesel starting sequence including the quantity (cfm) of air used in each start and the rpm when the solenoid valve (start valve) shuts.
3.
Provide a discussion on how compliance is met to requirements of IEEE Standard 387-1977, Sections 6.3.2 and 6.4. 1 with regard to the definition of an engine start, and Section 5.6.2.2( 1) with regard to automatic override while performing the diesel start test per Technical Specification 4.8.1.1.2.d.12.
- 4. " For each of the four emergency diesels, provide the following information:
a.
Air receiver pressure prior to each start b.
Star ting time for each of five starts c.
Classification of alarms associated with the air start system (e.g.,
low air pressure al*arm) d.
Ninimum manufacturer's recommended starting air pressure