Advises That Fatigue Cycling Discussed in Util Has Not Been Completely Addressed,Per 820726 Telcon.Effects on NSSS Equipment Should Be Evaluated.Addl Discussions of Item Provided in SER Suppl 3
ML17139A915
Person / Time
Site: Susquehanna 
Issue date: 07/26/1982
From: Youngblood B
Office of Nuclear Reactor Regulation
To: Curtis N
PENNSYLVANIA POWER & LIGHT CO.
References
NUDOCS 8208110066
Download: ML17139A915 (4)


Text

SUL 2 6 1982 Docket No.:

50-387 Mr. Norman W. Curtis Vice President Engineering and Construction-Nuclear Pennsylvania Power 5 Light Company 2 North Ninth Street Allentown, Pennsyl vania 18101 4

DISTRIBUTION:

] Document Control (50-387)

'RC" PDR L

PDR NSIC TERA ACRS (16)

LB82 Rdg.

MRushbrook RPerch

Attorney, OELD OIE

Dear Mr. Curtis:

Subject:

Fatigue Cycling - Susquehanna Steam Electric Station, Unit 1 As discussed in a telephone conference call on July 26, 1982 between W. Williams (PPKL) and R. Perch (NRC), the topic of fatigue cycling discussed in PPSL letter dated July 14, 1982 has not been completely addressed.

While submittals to date have adequately addressed the fatigue cycling effects due to safety relief valve (SRV) loads for balance of plant equipment, a similar evaluation must be made for fatigue effects on NSSS equipment.

Additional discussions of this item have been provided in Supplement No.

3 to the Susquehanna Safety Evaluation Report.

Sincerely, OI igiXtGQ ~$ P'~gOri IIPe

~

Steyhor 4

Ca~,ZI t cc:

See next page B. J. Youngblood, Chief

~

~

Licensing Branch No.

1 Division of Licensing 82081i006b 82072b PDR ADQCK 05000387

'P PDR.

OFFICE/

SURNAME/

DATE$

DL:LBg2 RPerch/lg 772'Q"82---

L:LBgl BJYoungbloo

~l-'782----'RG FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USG PO: 1981~~860

J I 0]$

n 'y

Susquehanna (t

Mr. Hor&n M. Curtis YicwPresident E ngi neeri ng and Cons true ti on Pennsylvania Power

& Light Company Allentown, Pennsylvania 18101 ccs:

Jay Silberg, Esquire Shaw, Pittman, Potts

& Trowbridge 1800 N Street, H.

M.

Washington, D.

C. 20036 Edward N. Hagel, Esquire General Counsel and Secretary Pennsylvania Power

& Light Company 2 Horth Hinth Street Allentown, Pennsylvania 18101 Mr. William E. Barberich Huclear Licensing Group Supervi sor Pennsylvania P ower

& Light Company 2 Horth Hinth Street Al1entown, Pennsyl vani a'8101 Mr. G. Rhodes Resident Inspector

" P. 0.

Box 52 Shickshinny, Pennsyl vania 18655 Gerald R. Schultz, Esquire Susquehanna Envi rormental Advocates P. 0.

Box 1560 Mi1k e s-8 arre, P ennsy 1 va ni a 18703 Nr. E. B. Poser Project Engineer Bechtel Power, Corporation P. 0.

Box 3965 Sari Francisco, Cali fornia 94119 Ns. Colleen Marsh P.

0.

Box 538A, RD 84 Mountain Top, Pennsyl vania 18707 Nr. Thomas J. Halligan Correspondent The Citizens Against Huclear Dangers P. 0.

Box 5

Scranton, P ennsy1 va ni a 18501 Nr. J.

M. Nillard Project Manager Nail Co¹ 395 General Electric Company 175 Curtner Avenue San Jose, California 95125 Robert W. Adler, Esquire Office of Attorney General 505 Executive House P. 0.

Box 2357 Harri sburg, P ennsyl va ni a 17120 Dr. J udi th H. J ohnsrud Co-Director Environmental Coalition on Huclear Power 433 Orlando Avenue State College, Pennsyl vania 16801 Nr. Thomas N. Gerusky, Director Bureau of Radiation Protection Resources Comrmnwealth of Pennsyl vania P. 0.

Box 2063 Harrisburg, Pennsy) vania 17120