ML17139A072

From kanterella
Jump to navigation Jump to search
Ack Receipt of Forwarding Interim Deficiency Rept Re Pipe Supports Welded to Containment Liner Plate.Matter Will Be Reviewed Following Receipt of Final Rept in May
ML17139A072
Person / Time
Site: Susquehanna 
Issue date: 03/19/1981
From: Keimig R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Curtis N
PENNSYLVANIA POWER & LIGHT CO.
References
NUDOCS 8104100329
Download: ML17139A072 (4)


Text

~pS REOII, c>

Np0 Cy

+

~O

~+*++

Docket No. 50-387 UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA19406 MAR 19 1981 Pennsylvania Power and Light Company ATTN:

Mr. Norman W. Curtis Yice President Engineering and Construction - Nuclear North Ninth Street Allentown, Pennsylvania 18101 Gentlemen:

Subject:

Pipe Supports Welded to Containment Liner Plate Iw

'h)/j%p 98I q ta Thank you for your letter PLA-653, dated March 6, 1981, which forwarded an interim report pursuant to 10 CFR 50.55(e) regarding the subject matter.

This matter will be reviewed following receipt of your.final report in May, 1981.

Your cooperation with us is appreciated.

Sincerely, Richard R.

eimig, ief Reactor Projects Branch 82 Division of Resident and Project Inspection CC:

A. R. Sabol,

Manager, Nuclear guality Assurance W. E. Barberich, Licensing Engineer H.

W. Keiser, Superintendent of Plant

N 1

'L w/>>

TWO NORTH NINTH STREET,.ALLENTOWN, PA. 18101, PHONEr (215) 770-5151 NORMAN W. CURTIS Vice President-Engineering rL Construction-Nuclear 7705 38 I March 6, 1981 Mr. Boyce H. Grier

'irector, Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 SUSQUEHANNA STEAM ELECTR1C STATION STATUS UPDATE OF A DEFICIENCY RELATING TO PIPE SUPPORTS WELDED TO CONTAINMENT LINER PLATE ERs 100450/100508 FILES 840-4/900-10 PLA-653

Reference:

PLA-489 dated 5/29/81

Dear Mr. Grier:

This letter serves to supplement the above referenced correspondence which advised the Commission of a deficiency involving pipe supports welded to the containment liner plate.

Bechtel Engineering has advised PPGL that the resolution of this subject has been determined to be more complex than originally anticipated.

We now estimate that a final report, pursuant to the recuirements of 10 CFR 50.55(e), will be available in May, 1981.

Very truly yours, N.

W. Curt.is Vice President>>Engineering a Construction-Nuclear FLW:sab PENNSYLVANI* POWER a LIGHT COMPANY

Mr. Boyce H. Grier March 6, 1981 cc:

Mr. Victor Stello (15)

Director-Office of Inspection 6 Enforcement U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. G. McDonald, Director (1)

Office of Management Information 6 Program Control U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. Robert M. Gallo U.. S. Nuclear Regulatory Commission P.

O. Box 52 Shickshinny, PA 18655