8 R60 c~

yA.

0O

++**+

Docket No. 50-387 50-388 UNITED STATES NUCLEAR REGULATORY COMMISSlO REGION I 63I PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA I 9406 QEC 3~ tSSO

~m~~'

Pennsylvania Power 8 Light Company ATTN:

Mr. Norman M. Curtis Vice President Engineering and Construction - Nuclear 2 North Ninth St.

Al'1entown, PA 18101 Gentlemen:

Subject:

Deficiency in Pilot Solenoid Valve Classification Thank you for your letter, PLA-588, dated December 16, 1980,'hich forwarded an interim report pursuant to 10 CFR 50.55(e) regarding the subject matter.

This matter will be reviewed following receipt of your final report in February 1981.

Your cooperation with us is appreciated.

Sincerely, Robert T. Carlson, Chief Reactor Construction and Engineering Support Branch cc:

A. R. Sabol,

Manager, Nuclear guality Assurance M. E. Barberich, Licensing Engineer H.

M. Keiser, Superintendent of Plant

I gl 1

>~'/g g~