ML17138B686

From kanterella
Jump to navigation Jump to search
Forwards Suppl 4 to IE Bulletin 80-17, Failure of 76 of 185 Control Rods to Fully Insert During Scram at Bwr. No Written Response Required
ML17138B686
Person / Time
Site: Susquehanna  
Issue date: 12/18/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Curtis N
PENNSYLVANIA POWER & LIGHT CO.
References
NUDOCS 8101070058
Download: ML17138B686 (1)


Text

~g REgy c"

0 Cy OO e

/4

()

++*++

Docket Nos.

50-387 50-388 UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA19406 DCC:1 S

J9gQ, C'/l K~1

~CJ

&1 CA~

KB Pennsylvania Power and Light Company ATTN:

Mr. Norman W. Curtis

.Vice President Engineering and Construction - Nuclear 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Gentlemen:

The enclosed Supplement No. 4 to IE Bulletin No. 80-17, "Failure of Control Rods to Insert During a Scram at a BWR," is forwarded to you for information.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Si ncerely,'ce H. Grier

'irector

Enclosures:

Supplement No.

4 to IE Bulletin No. 80-17 2.

List of Recently Issued IE Bulletins CONTACT:

D.

L. Caphton (235-337-5266) cc w/encls:

A.

R. Sabol,

Manager, Nuclear guality Assurance W.

E. Barberich, Licensing Engineer H.

W. Keiser, Superintendent of Plant 61010vo DM