Category:Memoranda
MONTHYEARML24128A2102024-05-0707 May 2024 Public Meeting Summary - 2023 Annual Assessment Meeting Regarding Saint Lucie ML24047A2092024-02-22022 February 2024 Calendar Year 2023 Baseline Inspection Completion ML23166A0042023-06-15015 June 2023 Summary of Meeting Concerning 2023 Annual Assessment of the Saint Lucie and the Turkey Point Nuclear Plants ML22188A0862022-07-0707 July 2022 SLRA - Audit Report ML22145A3932022-05-25025 May 2022 Public Meeting Summary 2021 Annual Assessment Meeting 20220434 ML21337A1962021-12-16016 December 2021 Public Scoping Meeting Summary for the Environmental Review of the Subsequent License Renewal Application for St. Lucie Plant, Units 1 and 2 ML21159A1352021-06-0808 June 2021 Public Meeting Summary Regarding the Saint Lucie Nuclear Plant, Units 1 and 2, Docket No. 50-335 and 389, and the Turkey Point Nuclear Generating Station Units 3 and 4, Docket No. 50-250 and 50-251; Meeting Number 20210505 ML20150A4732020-05-29029 May 2020 EOC Meeting Summary ML19121A6102019-05-0101 May 2019 Public Meeting Summary - St Lucie Nuclear Plant, Docket Nos. 50-389 and 50-335 ML18144A1452018-05-24024 May 2018 Public Meeting Summary - St. Lucie Nuclear Plant Docket Nos. 50-335 and 50-389 ML17103A0342017-04-12012 April 2017 Summary of Category 1 Public Meeting to Discuss the Significance Determination Process for a Finding at St. Lucie, Unit 1 ML16097A1302016-04-0404 April 2016 March 29, 2016 Summary of Public Meeting - 2015 Annual Assessment Regarding Saint Lucie ML15320A5512015-11-23023 November 2015 SER MF5835 ML15240A1542015-09-0808 September 2015 Staff Observations of Sump Strainer Head Loss Testing at Alden Laboratory for Generic Safety Issue 191 ML14163A6522014-06-19019 June 2014 Summary of May 29, 2014, Public Meeting with NextEra Energy, Inc. and Florida Power & Light Company Regarding Proposed Amendment to Transition Fuel Type at St. Lucie Unit 2 ML14156A2132014-06-0404 June 2014 Public Meeting Summary - St. Lucie Nuclear Plant Docket Nos. 50-335 and 50-389 ML13059A5522013-03-0101 March 2013 3/14/13 - Forthcoming Meeting with Florida Power and Light Company Regarding Steam Generator Performance at St. Lucie Nuclear Plant, Units 1 and 2 ML12222A0392012-08-0909 August 2012 8/16/2012 Cancellation Notice of Forthcoming Conference Call with NextEra Energy and Florida Power and Light Concerning Generic Letter 2004-02 and Request for NRC Staff Review of Draft Proposed Guideline for Strainer Fiber Bypass Test Proto ML12213A0612012-08-0101 August 2012 8/16/12 Forthcoming Conference Call with NextEra Energy and Florida Power & Light Concerning Generic Letter 2004-02 and Request for NRC Staff Review of Draft Proposed Guideline for Strainer Fiber Bypass Test Protocol ML12150A2992012-06-0505 June 2012 May 17, 2012, Summary of Teleconference Held Between the U.S. Nuclear Regulatory Commission, U.S. Fish and Wildlife Service, and Florida Power & Light Co. to Discuss the Terms of the Biological Opinion at the St. Lucie Plant, Units 1 and 2 ML1204005162012-02-0909 February 2012 Notification of Inspection and Request for Information for NRC Problem Identification and Resolution Inspection ML11251A0052011-09-0909 September 2011 9/21/11 Notice of Forthcoming Meeting with Florida Power and Light Regarding St. Lucie Nuclear Plant, Units 1 and 2 Extended Power Uprate ML11231A7172011-08-25025 August 2011 Notice of Forthcoming Meeting with Florida Power and Light Company (FPL) Regarding Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors. ML11182A0142011-07-0101 July 2011 Forthcoming Meeting with Florida Power & Light Company Regarding St. Lucie Nuclear Plant, Unit 1 to Discuss Extended Power Uprate License Amendment Request That Is Currently Under Review ML1109006712011-04-21021 April 2011 Acceptance of License Amendment Request for an Extended Power Uprate (Epu), St Lucie Nuclear Plant ML1106104272011-03-0707 March 2011 Notice of Forthcoming Pre-Application Meeting with Florida Power & Light Company and NextEra Energy Regarding Turkey Point, Units 3 and 4, St. Lucie, Units 1 and 2, Point Beach, Units 1, and 2, and Duane Arnold ML1035405732010-12-21021 December 2010 Acceptance of License Amendment Request for an Extended Power Uprate (Epu), St. Lucie Nuclear Plant, Unit 1 ML1025601362010-09-0707 September 2010 Notice of Meeting with Florida Power & Light Company to Discuss the Florida Power & Light Company'S Forthcoming Applications for the Extended Power Uprates of St. Lucie Units 1 & 2 and Turkey Point Units 3 & 4, Focusing on the Topic of Spen ML0921805182009-08-0606 August 2009 Notice of Public Meeting with Florida Power & Light Energy ML0909705822009-04-0707 April 2009 Phone Call Summary with Licensees and Alion Science and Technology on April 2, 2009 to Address NRC Staff Position on Chemical Effects Refinements ML0832502332008-12-0202 December 2008 Summary of Public Meeting with Operators of Vogtle Units 1 & 2, San Onofre Units 2 & 3, St. Lucie Unit 1, Turkey Point Unit 3, Indian Point Units 2 & 3, Nuclear Energy Institute, and Alion Science and Technology ML0826006252008-09-16016 September 2008 Draft Request for Additional Information on Relief Request No. 2 Regarding Structural Weld Overlays ML0820008422008-07-18018 July 2008 Memorandum of the Secretary (Referring a Petition to Intervene to the ASLBP) ML0807400842008-03-14014 March 2008 Draft Regulatory Guide for Comment ML0810502852008-03-11011 March 2008 NDE Report, on PSL-1 Pressurizer Nozzles, Attachment 3 ML0635602592006-12-27027 December 2006 Forthcoming Meeting with Florida Power and Light to Discuss Proposed License Amendment Request to Adopt Alternate Source Term at the St. Lucie Nuclear Plant ML0633303802006-11-29029 November 2006 Forthcoming Meeting with Florida Power & Light Regarding Proposed License Amendment Request to Adopt Alternate Source Term at St. Lucie Nuclear Plant ML0614505922006-05-26026 May 2006 Wits 200600198 - Actions to Be Taken in Response to Hurricane Lessons Learned Task Report ML0609602052006-04-0606 April 2006 Meeting Notice, Florida Power & Light, St. Lucie Unit 2, Steam Generator Tube Inspection During Refueling ML0523704412005-08-31031 August 2005 Closeout Letter for Bulletin 2003-01, Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors. ML0517402732005-06-23023 June 2005 Notice of Meeting with Florida Power and Light Company (FPL) & Westinghouse LAR to Increase SG Tube Plugging at St. Lucie ML0502701092005-01-25025 January 2005 Safety Evaluation on the Relief Request 2 Associated with the Third 10-year Inservice Inspection Interval - Inservice Inspection Program for St. Lucie Unit 2 ML0419005722004-07-0101 July 2004 Ltr, Temporary Change in Personnel Assignment ML0326809972003-10-0909 October 2003 Renewal of Full-Power Operating Licenses for St. Lucie, Units 1 and 2 ML0324005942003-08-25025 August 2003 June 10-11, 1997, Summary of NRC Senior Management Meeting to Review Performance of Operating Nuclear Power Plants and Materials Facilities Licensed by Nrc. Partially Withheld ML0321800032003-08-0606 August 2003 08/20-21/2003 Notice of Meeting with Florida Power and Light Regarding Increased Steam Generator Tube Plugging and Reload Methodology at St. Lucie, Unit 2 ML0316210252003-06-11011 June 2003 Peer Review of Risk-informed Safety Evaluation of the Suppression Capability in the Cable Spreading Room at St. Lucie Nuclear Power Plant Unit 1 ML0312702872003-05-0707 May 2003 Submission of Draft Request for Additional Information and Summary of a Conference Call Regarding Steam Generator Tubesheet Amendment ML0309808612003-04-0909 April 2003 Corrected Notice for Meeting with FPL to Discuss Requests for Relaxation from Reactor Pressure Vessel Head Inspection Order at St.Lucie, Unit 2 ML0309306732003-04-0303 April 2003 Meeting with FPL to Discuss Requests for Relaxation from Reactor Pressure Head Inspection Order at St. Lucie 2024-05-07
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 245 PEACHTREE CENTER AVENUE NE, SUITE 1200 ATLANTA, GEORGIA 30303-1257 April 12, 2017 MEMORANDUM TO: LaDonna B. Suggs, Chief Reactor Projects Branch 3 Division of Reactor Projects FROM: Lundy Pressley, Senior Project Engineer /RA/
Reactor Projects Branch 3 Division of Reactor Projects
SUBJECT:
SUMMARY
OF CATEGORY 1 PUBLIC MEETING TO DISCUSS THE SIGNIFICANCE DETERMINATION PROCESS FOR A FINDING AT ST. LUCIE UNIT 1 DATE, TIME: Tuesday, March 21, 2017, 9:30 a.m. - 12:00 p.m. (OPEN)
LOCATION: NRC Region II Office, Marquis One Tower 245 Peachtree Center Avenue, NE, Suite 1200 Atlanta GA 30303-1257 PURPOSE: To provide an opportunity for the licensee to present additional information related to a Finding at St. Lucie Unit 1 that was preliminarily determined to be of White significance.
U.S. Nuclear Regulatory Commission Public Meeting Summary March 21, 2017
Title:
Category 1 Public Meeting to Discuss the Significance Determination Process for a Finding at St. Lucie Unit 1 Meeting Identifier: 20170306 Date of Meeting: Tuesday, March 21, 2017 Location: Region II Office, Atlanta, GA Type of Meeting: Category 1 Purpose of the Meeting:
To provide an opportunity for the licensee to present additional information related to a Finding at St. Lucie Unit 1 that was preliminarily determined to be of White significance. The details of the Preliminary White Finding are available in Inspection Report 2016012 (ML17033B599).
General Details:
The NRC conducted a Category 1 open Regulatory Conference beginning at 9:30 a.m. on March 21, 2017, between members of NextEra subsidiary Florida Power and Light (FPL) and NRC Region II staff and Headquarters staff via videoconference. The meeting was approximately two and half hours in length.
The agenda for the meeting was as follows:
- Opening remarks and introduction
- Statement of the issue and finding
- NextEra / FPL presentation
- Break / NRC internal discussion
- Public questions The following FPL personnel were present:
- T. Summers, Regional Vice President, Southern Region
- L. Nicholson, Director, Nuclear Licensing & Regulatory Affairs
- A. Julka, Fleet PRA Manager
- M. Jones, Site Engineering Director, St. Lucie
- S. Merrill, Shift Manager, St. Lucie
- M. Snyder, Site Licensing Manager, St. Lucie
L. Suggs 3 The following NRC Region II staff members were present:
- C. Haney, Regional Administrator
- L. Wert, Deputy Regional Administrator
- J. Munday, Director, Division of Reactor Projects
- M. Franke, Deputy Director, Division of Reactor Projects
- L. Suggs, Chief, Reactor Projects Branch 3
- M. Kowal, Enforcement Team Lead
- J. Hanna, Senior Reactor Analyst
- L. Pressley, Senior Project Engineer, Reactor Projects Branch 3
- A. Wilson, Project Engineer, Reactor Projects Branch 3 The following NRC staff members attended via bridgeline or video teleconference:
Via bridgeline:
- T. Morrissey, Senior Resident Inspector, St. Lucie,
- S. Roberts, Resident Inspector, St. Lucie Via videoconference:
- M. Gavrilas, Deputy Director, Division of Risk Assessment, NRR
- C. Miller, Director, Division of Inspection and Regional Support, NRR
- P. Peduzzi, Deputy Director, Office of Enforcement
- J. Peralta, Chief Enforcement Branch
- D. Jones, Enforcement Specialist
- G. Casto, Branch Chief, PRA Licensing Branch, NRR
- J. Circle, Team Leader, PRA Operations and Human Factors Branch, NRR
- S. Wong, Senior Reactor Analyst, NRR
- B. Hartle, Risk Analyst, NRR
- B. Beasley, Chief, Plant Licensing Branch, NRR
- P. Buckberg, Senior Project Manager, NRR Additional NRC personnel were in attendance for observation or training purposes. There were also multiple FPL personnel from the St. Lucie site and from corporate listening to the meeting via the bridgeline. One member of the public joined the bridgeline after the business portion of the meeting had concluded.
Regional Administrator C. Haney opened the meeting with introductions and brief comments regarding the purpose of the meeting and a review of the meeting ground rules. Division of Reactor Projects Director J. Munday provided commentary on the NRCs perspective of the finding and provided an overview of the NRCs timeliness goals with resolving the issue.
The meeting was then turned over to FPL personnel.
Summary of Presentation:
The FPL presentation consisted of a PowerPoint presentation, which is available for public review (ML17072A376), and an approximately 8 minute video that is not available via ADAMS due to technological limitations, however specific details of the video are contained within the FPL PowerPoint presentation. The video demonstrated power restoration
L. Suggs 4 scenarios from a loss of offsite power and a station blackout using the St. Lucie simulator.
The remaining aspects of the FPL presentation focused on three specific cases which would reduce the risk of the event to below 1E-06.
After the FPL presentation concluded the meeting was briefly suspended for an NRC internal discussion and break. After an approximate 20 minute break the meeting then resumed. During the meeting the NRC staff asked specific questions regarding the FPL presentation. Following the break, NRC staff and FPL personnel addressed any follow-up questions and determined there were no additional items needed from the presentation.
Regional Administrator C. Haney then provided closing remarks to the conference and opened the bridgeline for any comments or questions from the public.
Public Participation:
There were no members of the public in attendance at the conference. No public meeting feedback forms have been received. One member of the public called into the bridgeline and indicated that they had missed the business portion of the meeting. However, during the brief question and answer session, the individual took the opportunity to ask questions that were unrelated to the topic of the meeting. NRC took the name and contact information of the individual and provided answers to post meeting questions on the following topics:
- Specifics on the recent Creusot Forge issue as it relates to St. Lucie. What actions are being taken?
- The latest information related to St. Lucie steam generator tube issues, specifically, the anti-vibration tubes on the steam generator and the rate of increase.
Action Items/Next Steps:
- NRC staff will assess the information provided by FPL during this meeting as part of the process to determine a final significance of the finding. The final determination will be documented in Inspection Report 2017011.
- Information was provided to the member of the public on the topics listed above.
References:
ML17103A034 SIGNATURE RII:DRP RII:DRP NAME LPressley LSuggs DATE 4/12/2017 4/12/2017