Technical Specifications Task Force A Joint Owners Group Activity TSTF TSTFPreSubmittalMeetingfor TSTF564,"SafetyLimitMCPR[Minimum CriticalPowerRatio]"
November1,2016 RyanJoyce ViceChair,BWROGLicensingCommittee 1
Technical Specifications Task Force A Joint Owners Group Activity TSTF Introduction
- Today'smeetingistodiscussTSTFtravelerTSTF564, "SafetyLimitMCPR,"whichtheTSTFplanstosubmittothe NRCforapproval.
SL2.1.1.2,forBoilingWaterReactor(BWR)plantsusing GlobalNuclearFuelorWestinghousefuel.
- AdraftofthetravelerwasprovidedtotheNRCpriortothe meeting.
- TheTSTF'sgoalforthismeetingistoensurethatthe submittalprovidesthenecessaryandsufficientinformation fortheNRCtoefficientlyreviewthetraveler.
2
Technical Specifications Task Force A Joint Owners Group Activity TSTF Introduction
- Thiseffortissupportedby:
- TheBoilingWaterReactorsOwners'Group (BWROG)LicensingCommittee
- TheTechnicalSpecificationsTaskForce
- TheBWROGReloadAnalysisandCore ManagementCommittee(RACMC)
- GlobalNuclearFuel(GNF)
- WestinghouseElectric 3
Technical Specifications Task Force A Joint Owners Group Activity TSTF CurrentRequirements
- Title10oftheCodeofFederalRegulations(10CFR),
Part50,paragraph50.36(c)(1)(i)(A),inpart,states:
Safetylimitsfornuclearreactorsarelimitsupon importantprocessvariablesthatarefoundtobe necessarytoreasonablyprotecttheintegrityof certainphysicalbarriersthatguardagainstthe uncontrolledreleaseofradioactivity.
4
Technical Specifications Task Force A Joint Owners Group Activity TSTF CurrentRequirements
- NUREG1433andNUREG1434,theBWR/4and BWR/6StandardTechnicalSpecifications(STS),
respectively,defineMinimumCriticalPowerRatio (MCPR)inSection1.1,"Definitions,"as:
TheMCPRshallbethesmallestcriticalpower ratio(CPR)thatexistsinthecore[foreachclass offuel].TheCPRisthatpowerintheassembly thatiscalculatedbyapplicationofthe appropriatecorrelation(s)tocausesomepointin theassemblytoexperienceboilingtransition, dividedbytheactualassemblyoperatingpower.
5
Technical Specifications Task Force A Joint Owners Group Activity TSTF CurrentRequirements
- STSSafetyLimit2.1.1.2states:
Withthereactorsteamdomepressure785psig andcoreflow10%ratedcoreflow:
MCPRshallbe[1.07]fortworecirculationloop operationor[1.08]forsinglerecirculationloop operation.
- Thereactorsteamdomepressureandcoreflowlimit mayvarybyplant.
6
Technical Specifications Task Force A Joint Owners Group Activity TSTF CurrentRequirements
- TheSLMCPRvalueiscalculatedasthepointatwhich 99.9%ofthefuelrodswouldnotbesusceptibleto boilingtransition.
- Itisrecognizedthattheonsetoftransitionboiling wouldnotnecessarilyresultindamagetoBWRfuel rods,butthecriticalpoweratwhichboiling transitioniscalculatedtooccurhasbeenadoptedas aconvenientlimit.
7
Technical Specifications Task Force A Joint Owners Group Activity TSTF CurrentRequirements
AllMCPRs shallbegreaterthanorequaltothe MCPRoperatinglimitsspecifiedintheCOLR[Core OperatingLimitsReport].
- TS3.2.2isapplicablewhenThermalPoweris25%
RTP(ratedthermalpower),oraplantspecific thermalpowerlimit.
8
Technical Specifications Task Force A Joint Owners Group Activity TSTF CurrentRequirements
- TheSLMCPRlimitiscalculatedforeachBWRonacycle bycyclebasisusingNRCapprovedmethodologies.
- TheSLMCPRlimitensuresthatnofueldamageresults duringnormaloperation.
- TheOperatingLimitMCPR(OLMCPR)valuesspecifiedin thelicenseecontrolledCOLRaredeterminedusingNRC approvedmethodologieslistedinSection5.6,"Core OperatingLimitsReport(COLR),"oftheTS.
- TheOLMCPRlimitsensurethatnofueldamageresults duringanticipatedoperationaloccurrences(AOOs)by confirmingtheSLMCPRisnotviolatedduringanAOO.
9
Technical Specifications Task Force A Joint Owners Group Activity TSTF NeedforChange
- ThecurrentmethodusedtodeterminetheSLMCPR valueresultsinfrequent,acceleratedlicense amendmentsthatunnecessarilychallengethe licenseeandtheNRC.
- Thecyclespecificcoredesignisdependentonthe previouscycleburnup,sothedesignforthesubsequent cycleistypicallyfinalizedlateinthepreviousfuelcycle.
- ThecurrentSLMCPRvalueisaffectedbythecycle specificdesign,suchascorepowerdistribution,fuel type,andoperatingpowerflowdomain.
10
Technical Specifications Task Force A Joint Owners Group Activity TSTF NeedforChange
- IftheSLMCPRvalueforthesubsequentcycleisless conservativethanthecurrentTS,aTSchangeisneeded.
- SubmittalstomodifytheSLMCPRtypicallyrequestan acceleratedNRCreview(i.e.,lessthanoneyear)to supportthescheduledstartofthesubsequentfuelcycle.
- TheTSTFidentified10requeststorevisetheSLMCPR valueapprovedin2015and2016.
- TheaveragelicenseerequestedNRCreviewtimewas 7months.
- 7of10requestedareviewin6monthsorless.
11
Technical Specifications Task Force A Joint Owners Group Activity TSTF NeedforChange
- TherearemethodsofdeterminingtheSLMCPRthat arenotcycledependentandsatisfytheregulations.
- TheequivalentPWR(Babcock&Wilcox,Westinghouse, CombustionEngineering,andAP1000)safetylimitis basedonaDeparturefromNucleateBoilingRatio(DNBR) limit,whichissimilartotheBWRSLMCPR.
- ThePWRsafetylimitisonlydependentontheDNBR correlationsforthefueltype(s)inthereactor.
- ThePWRDNBRsafetylimitisnotcycledependentandis typicallyonlyrevisedwhenthefueltypechanges.
12
Technical Specifications Task Force A Joint Owners Group Activity TSTF ProposedChange
- TheproposedchangerevisestheSLMCPR methodologyforallBWRplantsusingGNFor Westinghousefuel.
- TSTF564isnotapplicabletoBWRplantsusing AREVAfuel.
- Theproposedchangewillsubstantiallyreducethe needforcyclespecificchangestotheSLMCPRand theneedforacceleratedNRCreviewofthose changes.
13
Technical Specifications Task Force A Joint Owners Group Activity TSTF ProposedChange
- Forplantsadoptingtheproposedchange,Safety Limit 2.1.1.2isrevisedtostate:
Withthereactorsteamdomepressure 785psig andcoreflow10%ratedcoreflow:
MCPRshallbe[1.07].
NochangesareproposedtotheMCPRdefinitioninTS Section1.1orTS3.2.2,"MCPR."
14
Technical Specifications Task Force A Joint Owners Group Activity TSTF ProposedChange
- ThefuelproductspecificSafetyLimitMCPRvalueis determinedbasedontheproduct'sexperimentally determinedcriticalpowerratioandastatisticalanalysisthat providesa95%probabilityata95%confidencelevel(95/95) fortheonesideduppertolerancelimitthatdependsonthe numberofsamplesinthecriticalpowerdatabase.
15 Vendor FuelType ProposedSLMCPR GNF GE14 1.06 GNF GNF2 1.07 Westinghouse Optima2 1.06 Westinghouse Optima3 1.06
Technical Specifications Task Force A Joint Owners Group Activity TSTF ProposedChange
- ProposethatGNFandWestinghousesendproprietary lettersdescribinghowtheSLMCPRvaluesare determinedbasedontheproprietaryCPRstatistics,tobe referencedinthetraveler.
- ForcoresloadedwithamixofGNForWestinghousefuel products,theSLMCPRisbasedonthelargest(i.e.,most limiting)oftheSLMCPRvaluesforthefuelproductsthat arefreshoronceburntatthestartofthecycle.
- IntheSTS,theexistingphrase"fortworecirculationloop operationor[1.08]forsinglerecirculationloop operation"willberetainedasaplantspecificoption(i.e.,
bracketed)forBWRplantsthatdonotadoptthetraveler.
16
Technical Specifications Task Force A Joint Owners Group Activity TSTF ProposedChange
- TheSafetyLimit2.1.1.2BasesandTS3.2.2Basesare revisedtoreflecttheproposedchange.
- IntheSTS,brackets(indicatingplantspecific information)andReviewer'sNotesareusedtoadd thenewinformationwhileretainingtheexisting descriptionforplantsthatdonotadoptthe proposedchange.
17
Technical Specifications Task Force A Joint Owners Group Activity TSTF BasisforChange
- ThemethodofcalculationfortheSLMCPRisrevised fromensuringthat99.9%oftherodswouldnotbe susceptibletotransitionboilingtoensuringthat thereisa95%probabilityata95%confidencelevel thatnorodswillbesusceptibletotransitionboiling basedonthecorrelationstatisticsalone.
- ThisisconsistentwiththePWRDNBRsafetylimit, whichcorrespondstoa95%probabilityata95%
confidencelevelthatDNBwillnotoccurbasedon thecorrelationstatisticsalone.
- Bothstatisticalapproachesareacceptable.
18
Technical Specifications Task Force A Joint Owners Group Activity TSTF BasisforChange
- TheproposedSLMCPRisbasedonlyontheCPR correlationuncertaintydeterminedfortheGNFor Westinghousefueltype(s)inthereactor.
- ThisisconsistentwiththePWRDNBRSafetyLimit.
- Plantandcyclespecificuncertainties,includingSLO and TLO reactorflowuncertainties,arenolongerincludedin theSLMCPR,soonlyasinglelimitisneeded.
- Theplantandcyclespecificuncertainties,including reactorflow,willcontinuetobeincludedintheOLMCPR (TS3.2.2)limit.Therefore,themargintoboiling transitionremainsunchanged.
19
Technical Specifications Task Force A Joint Owners Group Activity TSTF BasisforChange
- Nochangestothemethodofdeterminingthe OLMCPR(i.e.,theLCO 3.2.2limit)areproposed.
- ThecurrentSLMCPRstatisticalcalculation (i.e.,MCPR99.9%)willcontinuetobeperformed usingtheNRCapprovedmethodology.
- TheOLMCPRCOLRlimitswillcontinuetobe determinedbycombiningthecyclespecific MCPR99.9%valueandthetransientCPR component.
20
Technical Specifications Task Force A Joint Owners Group Activity TSTF ProposedModelApplication
- Thetravelercontainsamodelapplicationforplant specificadoptionoftheproposedchange.
- Licenseesadoptingthetravelerusingthemodel applicationmustprovide:
- VerificationthatthetravelerandNRCsafety evaluationareapplicable.
- Thetypeoffueltobeinthereactorandthe proposedSafetyLimitbasedonthetableinthe travelerandtheReviewer'sNoteintheTSBases.
- Adiscussionofanyvariationsfromthetraveler, suchasTSnumberingortitles.
21
Technical Specifications Task Force A Joint Owners Group Activity TSTF Conclusion
- TherevisedSLMCPRmethodofcalculationforGNF andWestinghousefuelwillcontinuetomeetthe regulatorydefinitionofasafetylimitandprotectthe integrityofthefuelrodcladdingagainstthe uncontrolledreleaseofradioactivity.
22
Technical Specifications Task Force A Joint Owners Group Activity TSTF Discussion 23
Technical Specifications Task Force A Joint Owners Group Activity TSTF BackupSlides 24
Technical Specifications Task Force A Joint Owners Group Activity TSTF DeterminationofProposedSLMCPRvalue
- TheproposedSLMCPRvalueisdesignatedasMCPR95/95
- ForeachGNFandWestinghouseBWRfuelproduct (designatedi),theMCPR95/95(i) iscalculatedusingthat productsexperimentallydeterminedcriticalpowerstatistics asfollows:
MCPR95/95(i) =µi +i*i (Eq.1)
- Where,
µi isthemeanExperimentalCriticalPowerRatio(ECPR),
i isthestandarddeviationoftheECPRs,and i isastatisticalparameterchosentoprovide95%probabilityat95%
confidence(95/95)fortheonesideduppertolerancelimitthat dependsonthenumberofsamples(Ni)inthecriticalpower database.
iisafuelproductline,suchasGE14,GNF2,OPTIMA2,OPTIMA3,etc.
25
Technical Specifications Task Force A Joint Owners Group Activity TSTF StatisticalTreatmentofMCPR95/95 Thestatisticalparameter,i,iscalculatedusingformulasattributedto MaryGibbonsNatrella (1963)asrecommendedbytheNationalInstitute ofStandardsandTechnology(NIST)intheirEngineeringStatistics Handbook(Reference1).Fora95/95probability/confidencelevel,thei valuesareshowninthetablebelowasafunctionofdatabasesize(Ni).
StatisticalParameter,i,at(95/95) fortheOneSidedUpperToleranceLimit 26 DatabaseSize, Ni i
500 1.7625 750 1.7401 1000 1.7270 1250 1.7181 1500 1.7115 2000 1.7024
Technical Specifications Task Force A Joint Owners Group Activity TSTF StatisticalTreatmentofMCPR95/95 Assumingatypicalcriticalpowerdatabaseof1000datapointswithno bias(i.e.,µi =1.0),thefollowingtableillustratesrepresentative MCPR95/95(i) valuesasafunctionofthedatabasestandarddeviation.
RepresentativeMCPR95/95 ValuesforNi=1000 TheSLMCPRisdeterminedtotwodigitspastthedecimalusingstandard roundingpractices.
27 StandardDeviation,i
(%)
SLMCPR95/95 2.0 1.03 2.5 1.04 3.0 1.05 3.5 1.06 4.0 1.07 4.5 1.08 5.0 1.09