Amend 81 to License NPF-69,changing Surveillance Requirements in TS 4.9.6 to Reflect Appropriate Setpoints for Proposed Mod That Will Replace Existing Triangular Refueling Platform Mast
ML17059B969
Person / Time
Site: Nine Mile Point 
(NPF-69-A-081, NPF-69-A-81)
Issue date: 04/16/1998
From: Bajwa S
NRC (Affiliation Not Assigned)
To:
Shared Package
ML17059B970 List:
References
NUDOCS 9804210104
Download: ML17059B969 (8)


Text

gp,R RECII+

po 0O I

c V)0 qO

++*++

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 NIAGARAMOHAWKPOWER CORPORATION DOCKET NO. 50-410 NINE MILEPOINT NUCLEARSTATION UNIT2 AMENDMENTTO FACILITYOPERATING LICENSE Amendment No.-81 License No. NPF-69

1. The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Niagara Mohawk Power Corporation (the licensee) dated October 7, 1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter 1;

\\

B.

The facilitywilloperate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (I) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities willbe conducted in compliance with the Commission's regulations; D.

The issuance of this amendment willnot be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-69 is hereby amended to read as follows:

'78042i0104 9804kb PDR ADQCK 050004i0 P

PDR

(2)

Technical S ecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto, as revised through Amendment No91 are hereby incorporated into this license.

Niagara Mohawk Power Corporation shall operate the facilityin accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of the date of its issuance to be implemented upon completion and acceptance of modifications to replace the existing triangular refueling platfomi mast with'a Ge'neral'Electnc Model NF-500 mast'with an installed felevision camera and monitor system.

FOR THE NUCLEAR REGULATORYCOMMISSION

Attachment:

Changes to the Technical Specifications Date of Issuance:

Apri 1 16, 1998 S. Singh Bajwa, Director Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

ATTACHMENTTO LICENSE AMENDMENT AMENDMENTNO. 81 TO FACILITYOPERATING LICENSE NO. NPF-69 DOCKET NO. 50-410 Revise Appendix A as follows:

3/4 9-8

~Insert Pa e

3/4 9-8

E N

P E

ELIN P

IMITING NDITIONS FOR PERATI N

3.9.6 The refueling platform shall be OPERABLE and used for handling fuel assemblies or control rods within the reactor pressure vessel.

h d~liif41 i

I M ihi

.. pressure vessel.

hCIlQH:

With the requirements for refueling platform OPERABILITYnot satisfied, suspend use of any inoperable refueling platform equipment from operations involving the handling of control rods and fuel assemblies within the reactor pressure vessel after placing the load in a safe condition.

RVEILLANCEREQUIREMENTS 4.9.6 Each refueling platform crane or hoist used for handling of control rods or fuel assemblies within the reactor pressure 'vessel shall be demonstrated OPERABLE within 7 days before the start of such operations with that crane or hoist by:

a.

Demonstrating operation of the overload cutoff on the main hoist when the load exceeds 1600 +100/

pounds.

b.

Demonstrating operation of the overload cutoff on the frame mounted and monorail mounted auxiliary hoists when the load exceeds 1000 a 50 pounds.

C.

Demonstrating operation of the main and auxiliary hoist uptravel stops wh'en the grapple is lower than or equal to 7 feet 3 3/4 inches below the platform tracks.

d.

Demonstrating operation of the downtravel mechanical cutoff on the main hoist when grapple hook down travel reaches 4 inches below fuel assembly handle.

8.

Demonstrating operation of the slack cable cutoff on the main hoist when the load is less than 50 a 10 pounds.

Demonstrating operation of the loaded interlock on the main hoist when the load exceeds 700 +50/-0 pounds.

g.

Demonstrating operation of the redundant loaded interlock on the main hoist when the load exceeds 700 +50/% pounds.

I NINE MILE POINT - UNIT 2 3/4 9-8 Amendment No. 681

~

,~