Text
~PS R500 G+
~o
++*++
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON> D.C. 20555-0001 NIAGARAMOHAWKPOWER CORPORATION DOCKET NO. 50-410 NINE MILEPOINT NUCLEAR STATION UNIT2 AMENDMENTTO FACILITYOPERATING LICENSE Amendment No. 79 License No. NPF9
- 1. The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Niagara Mohawk Power Corporation (the licensee) dated July 31, 1997, co'mplies with the standards an'd requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter 1; B.
The facilitywilloperate in conformity with the application, the provisions of the Act, and the rules and'iegulations of the Commission;
-. C.
There is reasonable assurance (I) that the activities authorized by this amendment can be conducted without endangering the health'and safety of the public, and (ii) that such activities willbe conducted in compliance with the Commission's regulations; D.
The issuance of this amendment willnot be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license a'mendment, and paragraph 2.C.(2) of Facility Operating L'icense*No. NPF-69 is hereby amended to read as follows:
9803230i52 9803ih PDR ADQCK 050004i0 P
(2)
Technical S ecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A and the Environmental
, Protection Plan contained in'Apperi'dix B, both of which are attached hereto, as
- revised through Ame'ndment No. 79 are hereby incorporated into this license.
Niagara Mohawk Power Corporation shall operate the facilityin accordance with the Technical
-Specifications and the Environmental Protection Plan.
3.
This license amendment is effective as of the date of its issuance to be implemented within 30 days.
FOR THE NUCLEAR REGULATORY COMMISSION S. Singh Bajwa, Director Project Directorate I-1 Division of Reactor Projects - I/II
'ffice of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance:
March 16, 1998
~
~
I
0
~
\\
ATTACHMENTTO LICENSE AMENDMENTNO. 7 TO FACILITYOPERATING LICENSE NO. NPF-69 DOCKET NO. 50-410 Replace the following page "ofthe Appendix ATechnical Specifications with the attached page.
The revised page is identified by Amendment number and contains vertical lines indicating the areas of change.
Remove 3/4 3-34 Insert 3/4 3-34
~
i) dl VER N Y ORE LING SY TE T
IN T MENTA ACTION 32-
. With the number of OPERABLE channels less than required by the
,Minimum OPERABLE Channels per Trip Function requirement, within 24 h'o'urs declare the associated ADS Trip System or ECCS inoperable.
ACTION 33-ACTION 34-ACTION 35-ACTION 36-ACTION 37-ACTION 38-ACTION 39-With the number of OPERABLE channels less than required by the Minimum OPERABLE Channels per, Trip Function requirement, place the inoperable channel in tlie tripped condition within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
Not Used.
With the number of OPERABLE channels less than required by the
'inimum OPERABLE Channels per Trip Function requirement, restore the inoperable charinel to OPERABLE statu's within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or declare the'associated ADS valve or ECCS inoperable.
With the number of OPERABLE channels less than required by the Minimum OPERABLE Ch'annels per Trip Function requirement:
a.
With one channel inoperable, place the inoperable channel in the tripped condition within 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s* or declare the HPCS system inoperable.
b.
With more than one channel inoperable, declare the HPCS system inoperable.
With the number of OPERABLE channels less than required by the Minimum OPERABLE Channels per Trip Function requirement, place at least one inoperable channel in the tripped condition within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />" or declare the HPCS system inoperable.
With the number of OPERABLE channels less than the Total Number of Channels, declare the associated emergency diesel generator inoperable and take the ACTION required by Specification 3.8.1.1 or 3.8.1.2, as appropriate.
,With the number of OPERABLE channels one less than the Total Number, of Channels, place the inoperable channel in the tripped co'ndition within 1 hour~; operation may then continue until performance of the next'e'quired CHANNEL FUNCTIONALTEST.
The provisions of Specification 3.0.4 are not applicab'Ie.
NINE MILE POINT - UNIT 2 3/4 3-34 AMENDMENT NO. 6 ~79