ML17059B499

From kanterella
Jump to navigation Jump to search
Notification of Significant Licensee Meeting 97-36 W/Util on 970414 to Discuss Results of Nine Mile Point Unit 1 Core Shroud Weld Inspections & Core Shroud Stabilizer Exam Performed by NMPC
ML17059B499
Person / Time
Site: Nine Mile Point 
Issue date: 04/09/1997
From: Doerflein L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
97-36, NUDOCS 9704170068
Download: ML17059B499 (8)


Text

CATEGORY 2 REGULAT INFORMATION DISTRIBUTIONSTEM (RIDE)

ACCESSION NBR:9704170068 DOC.DATE: 97/04/09 NOTARIZED: NO DOCKET I FACIL:50-220 Nine Mile Point Nuclear Station, Unit 1, Niagara Powe 05000220 AUTH.NAMi AUTHOR AFFIL'IATION DOERFLEIN,L.T.

Region 1 (Post 820201)

RECIP.NAME RECIPIENT AFFILIATION Region 1 (Post 820201)

SUBJECT:

Notification of significant licensee meeting 97-36 w/util on 970414 to discuss results of Nine Mile Point Unit 1 core shroud weld inspections

& core shroud stabilizer exam performed by NMPC.

DISTRIBUTION CODE: IE45D 'COPIES RECEIVED:LTR g ENCL ~IEE:

3

'- TITLE: Summary of Significant Meeting with Licensee (Part 50)

NOTES:

A RECIPIENT ID CODE/NAME PD1-1 PD INTERNAL: DEDRO NRR/DISP/PIPB RES/DET/EIB EXTERNAL: NOAC COPIES LTTR ENCL 1

1 1

RECIPIENT ID CODE/NAME HOODFD LE CEN OGC/ROED RGN1 FILE 01 NRC PDR COPIES LTTR ENCL 1

1 1.

D C

U E

N NOTE TO ALL "RZDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE.'O HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)

ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES.REQUIRED:

LTTR 10 ENCL

0

April 9, 1997 No. 97-36 Revision 1

U.S. NUCLEAR REGULATORY COMMISSION REGION I

NOTICE OF SIGNIFICANT MEETING Licensee:

Facility:

Docket No:

Time and Date:

Location:

Niagara Mohawk Power Corporation (NMPC)

Nine Mile Point (NMP) Unit 1 50-220 5:00 p.m., Monday, April 14, 1997 Joint News Center 10 Airport Drive Fulton, NY 13069 (Directions: Adjacent to Oswego County Airport, off of County Route 176)

Purpose:

NRC Attendees:

Technical meeting to discuss the results of the Nine Mile Point Unit 1 core shroud'weld inspections and core shroud stabilizer examination performed by NMPC, B. Sheron, Director,'ivision of Engineering (DE), Office of Nuclear Reactor Regulation (NRR)

G. Lainas, Deputy Director, DE, NRR R. Wessman, Chief, Mechanical Engineering Branch, NRR R. Hermann, Senior Level Advisor, Materials 5 Chemical Engineering Branch (MCEB), (DE), NRR S. Bajwa, (Acting) Director, Project Directorate I-1 (PDI-1), NRR W. Koo, Senior Materials Engineer, MCEB, DE, NRR K. Kavanagh, Reactor Systems Engineer, Division of System Safety 5 Analysis, NRR D. Hood, Senior Project Manager, Project Directorate l-1, NRR L. Doerflein, Chief Projects Branch 1, Division of Reactor Projects (DRP), Region I

W. Lazarus, Chief,, Civil, Mechanical, Materials, Engineering Branch, Division of Reactor Safety (DRS), Region I

E. Gray, Senior Project Manager, DRS, Region I

B. Norris, Senior Resident Inspector, DRP, Region I

9704k 70068 970409 PDR ADQCK 05000220 P

PDR IIIIIIKIIIIIIIIIMlllllllllllllllllllll OFFICIAL-RECORD COPY IE:45

li

NMPC Attendees:

B. Sylvia, Executive'ice President, NMPC R. Abbott, Vice President 5 General Manager Nuclear, NMPC M. McCormick, Vice President-Nuclear Engineering, NMPC C. Terry, Vice President-Nuclear Safety Assessment 5.

Support, NMPC NOTE:

This technical meeting is open for public observation except those portions of the meeting where proprietary information is discussed.

At the conclusion of the technical discussions, time will be provided for questions and comments from the public. Attendance by additional NRC personnel or handicapped persons requiring assistance to participate in the'meeting should make their requests known to Lawrence T. Doerflein,'Chief, Projects Branch 1, USNRC, Region I, 475 Allendale Rd., King of Prussia, PA 19406, (610-337-5378), by April 11, 1997.

Prepared by Original Signed by:

Lawrence T. Doerflein, Chief Projects Branch 1

~

. Division of Reactor Projects Distribution (Via E-Mall):

L. Callan, Executive Director for Operations, OEDO H. Thompson, Deputy Executive Director for Regulatory Programs, OEDO E. Jordan; Deputy Executive Director for Regulatory Effectiveness, Program Oversight Investigations, and Enforcement, OEDO S. Collins, Director, Office of Nuclear Reactor Regulation A. Thadani, Deputy Director, Office of Nuclear Reactor Regulation T. Martin, Director, Division of Reactor Program Management, NRR D. Matthews, Acting Deputy Director, Division of Reactor Program Management, NRR D. Ross, Deputy Director, Office of Analysis and Evaluation of Operational Data, AEOD R. Spessard, Director, Division of Reactor Controls and Human Factors, NRR J. Lieberman, Director, Office of Enforcement R. Zimmerman, Associate Director for Projects, NRR S. Varga, Director, Division of Reactor Projects - I/II, NRR'.

Dean, Regional Coqrdinator, OEDO N. Green, Jr., Policy Development 6 Technical Support Branch S. Bajwa, Dir'ector, Project Directorate 1-1, NRR D. Hood, Project Manager, PD l-1, NRR D. Screnci, Public Affairs, Rl N. Sheehan, Field Public Affairs Officer, Rl M. Campion, ORA D. Chawaga, ORA

0

3 Distribution:

PUBLIC B. Sylvia, Executive Vice President Generation Business Group, Niagara Mohawk Power Corporation State of New York Regional Administrator Secretary, Rl Deputy Regional Administrator Secretary, Rl DRP Division Secretary, Rl DRS Division Secretary, Rl DNMS Division Secretary, RI

'RM Division Secretary, Rl Region I Receptionist DOCUMENT NAME: G ttBRANCH1A04-14-97.NMP To receive a copy of this document. Indicate In the born "C

~ Copy without attachment/enclosure

'E' Copy with attachment/enclosure "N" ~ No copy OFFICE

'RI/D RI/DRP NAME TMosla LDoerflein DATE 04

/97 04/

/97 COPY

0 C'