ML17059B019

From kanterella
Jump to navigation Jump to search
Forwards Response to NRC 951109 RAI Re NUREG-0619, BWR FW Nozzle & CRD Return Line Nozzle Cracking & GE Proprietary & Nonproprietary Documents.Ge Proprietary Documents Withheld Per 10CFR2.790
Date released: 06/30/2017 Download: ML17059B019


Forwards Response to NRC 951109 RAI Re NUREG-0619, BWR FW Nozzle & CRD Return Line Nozzle Cracking & GE Proprietary & Nonproprietary Documents.Ge Proprietary Documents Withheld Per 10CFR2.790
ML18040A240
Person / Time
Site: Nine Mile Point 
Issue date: 12/15/1995
From: Abbott R
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
RTR-NUREG-0619, RTR-NUREG-619
Download: ML18040A240 (47)
Rev 0 to UT-NMP-311V0, Procedure for Manual Ultrasonic Exam of Nozzles Inner Radius & Bore.
ML17059B022
Person / Time
Site: Nine Mile Point 
Issue date: 02/15/1995
From:
GENERAL ELECTRIC CO.
To:
References
Download: ML17059B022 (38)
Rev 0 to UT-NMP-309V0, Procedure for Manual Ultrasonic Exam of Planar Flaw Sizing for Nozzle Inner Radius & Bore Regions.
ML17059B021
Person / Time
Site: Nine Mile Point 
Issue date: 02/10/1995
From:
GENERAL ELECTRIC CO.
To:
References
Download: ML17059B021 (16)
Rev 0 to UT-NMP-703V0, Procedure for Geris 2000 Ultrasonic Exam of RPV Nozzle Inner Radius & Bore Regions.
ML17059B020
Person / Time
Site: Nine Mile Point 
Issue date: 02/10/1995
From:
GENERAL ELECTRIC CO.
To:
References
Download: ML17059B020 (30)
Feedwater Nozzle Analysis.
ML17059B018
Person / Time
Site: Nine Mile Point 
Issue date: 01/20/1995
From: Mortenson S, Self J
GENERAL ELECTRIC CO.
To:
References
Download: ML17059B018 (68)