ML17059A616

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Granting Util 940818 Request to Use of Code Case N-416-1 in Lieu of Performing Code-required Hydrostatic Pressure Test for Welded Repairs
ML17059A616
Person / Time
Site: Nine Mile Point  
Issue date: 01/13/1995
From: Michael Case
Office of Nuclear Reactor Regulation
To: Sylvia B
NIAGARA MOHAWK POWER CORP.
Shared Package
ML17059A617 List:
References
TAC-M90232, TAC-M90233, NUDOCS 9501200071
Download: ML17059A616 (8)


Text

~

~

I gwR Rgb

~..

P

~4+

o Cy C

I 0O IVl

~O

+a**+

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D,C. 2055&4001 January 13, 1995.

Hr. B. Ralph Sylvia Executive Vice President, Nuclear Niagara Mohawk Power Corporation Nine Hile Point Nuclear Station P.O.

Box 63

Lycoming, NY 13093

SUBJECT:

NINE MILE POINT NUCLEAR STATION, UNIT NOS.

1 AND 2 (NHP-1 AND NMP-2),

APPROVAL OF CODE CASE N-498-1 AS AN ALTERNATIVE TO THE REQUIRED HYDROSTATIC PRESSURE TEST (TAC NOS.

H90232 AND H90233)

Dear Hr. Sylvia:

By letter dated August 18, 1994, Niagara Mohawk Power Corporation (NHPC) requested approved to use American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASHE Code)

Case N-416-1 in lieu of performing the Code-required hydrostatic pressure test for welded repairs or installation of replacement items by welding and ASME Code Case N-498-1 in lieu of performing the required 10-year pressure test at NMP-1 and NHP-2.

NRC approval for NHPC to use ASHE Code Case N-416-1, with certain provisions, was issued by our letter and attached safety evaluation dated October 18, 1994.

However, as stated in our October 18, 1994, letter, the NRC staff's review of ASHE Code Case N-498-1 was incomplete at that time and, therefore, use of ASHE Code Case N-498-1 was not then approved.

The staff has now completed its review of the proposed use of ASME Code Case N-498-1 at NMP-1 and NHP-2.

Based on the information submitted, NHPC's alternative (ASHE Code Case N-498-1) is authorized pursuant to 10 CFR 50.55a(a)(3)(ii) since compliance with the specified requirements of Section XI of the ASHE Code would result in hardship or unusual difficultywithout a compensating increase in the level of safety and quality when applied to pressure testing at both NHP-1 and NHP-2.

NHPC's alternative, use of ASHE Code Case N-498-1, is authorized until such time as this code case is published in a future revision of Regulatory Guide 1.147.

At that time, if NHPC intends to continue to implement this Code

case, NHPC is required to follow all provisions in ASHE Code Case N-498-1 with limitations issued in Regulatory Guide 1. 147, if any.

'JO <2 9501200071 950113 It PDR ADOCK 05000220 P

PDRQ

J C

~

l~

~ I

B. Sylvia january 13, 1995 The staff's evaluation and conclusions regarding ASME Code Case N-498-1 are contained in the attached safety evaluation.

Sincerely, Docket Nos.

50-220 and 50-410

Enclosure:

Safety Evaluation cc w.encl:

See next page Distribution:

Docket File PUBLIC PDI-1 Reading SVarga JZwolinski MCase CVogan DBrinkman OGC ACRS (4)

CCowgi1 1, RGN-I KBattige JStrosnider Michael J.

ase, Acting Director Project Directorate I-1 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation DOCUMENT NAME:

G: iNMP1-2iNM90232. LTR To reeelve o oops of this dormment. Indleeto In the hoe:

C Cops without enotosures 'E'ops wijhlhn Ipkljres N'ilo oopy OFFICE LA:PDI-1 PM: PDI-1 g

BC: EMCB OGC /V D: PDI-1 NAME CVo an gP DBrinkman:smml JStrosnider MCas DATE 12/ I /94 1

LL 4 12/Ig/94 12/

494

-12~/.94 gg/g,a/qyOFFICIAL RECORD COPY

~h3/e

0

B. Sylvia january 13, 1995 The staff's evaluation and conclusions regarding ASHE Code Case N-498-1 are contained in the attached safety evaluation.

Sincer ely, Docket Nos.

50-220 and 50-410

Enclosure:

Safety Evaluation cc w/encl:

See next page Michael J.

Case, Acting Director Project Directorate I-1 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

B. Ralph Sylvia Niagara Mohawk Power Corporation CC:

Nine Mile Point Nuclear Station Unit Nos.

1 and 2

Hark J. Wetterhahn, Esquire Winston E Strawn 1400 L Street, NW Washington, DC 20005-3502 Supervisor Town of Scriba Route 8, Box 382

Oswego, NY 13126 Hr. Louis F. Storz Vice President Nuclear Generation Niagara Hohawk Power Corporation Nine Mile Point Nuclear Station P.O.

Box 63

Lycoming, NY 13093 Resident Inspector U. S. Nuclear Regulatory Commission P.O.

Box 126

Lycoming, NY 13093 Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, NY 13202 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Ms.

Donna Ross New York State Energy Office 2 Empire State Plaza 16th Floor

Albany, NY 12223 Mr. Hartin J. HcCormick, Jr.

Vice President Nuclear Safety Assessment and Support Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station P.O.

Box 63

Lycoming, NY 13093 Mr. Richard B. Abbott Unit 1 Plant Manager Nine Mile Point Nuclear Station P.O.'ox 63
Lycoming, NY 13093 Hr. Kim A. Dahlberg Plant Hanager, Unit 2 Nine Mile Point Nuclear Station P.O.

Box 63

Lycoming, NY 13093 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Hr. Paul D.

Eddy State of New York Department of Public Service Power Division, System Operations 3 Empire State Plaza

Albany, NY 12223 Hr. David K. Greene Manager Licensing Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station P.O.

Box 63

Lycoming, NY 13093 Hr. Richard Goldsmith Syracuse University College of Law E. I. White Hall Campus
Syracuse, NY 12223 Hr. Richard H. Kessel Chair and Executive Director State Consumer Protection Board 99 Washington Avenue
Albany, NY 12210