Docket Nos.

50-220

50-410

Mr. B. Ralph Sylvia

Executive Vice President - Nuclear

Niagara Mohawk Power Corporation

Nine Mile Point Nuclear Station

P. O. Box 63

Lycoming, New York 13093

Dear Mr. Sylvia:

Subject:

NRC Region I Combined Inspection Report Nos. 50-220/94-05 and

50-410/94-05

This letter transmits the results of the resident safety inspection conducted by Messrs.

B. Norris, R. Plasse,

and W. Mattingly from March 6 through April 16, 1994, at Nine Mile

Point Units 1 and 2, Scriba, New York. The inspectors based their findings on observation

of activities in progress,

interviews with personnel,

and selective examinations of procedures

and representative

records.

The resident inspectors discussed

the inspection findings with

you and members of your staff at the exit meeting conducted on April 28, 1994.

Your staff operated and performed forced outage maintenance at both units safely.

Control

room staff performance,

management

oversight of daily plant operations,

and your

organizations overall performance during the forced outages were noted strengths.

However,

some weaknesses

in engineering support during the Unit 1 startups were identified.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter and

its enclosures willbe placed in the NRC Public Document Room.

Your cooperation with us is appreciated.

Sincerely,

ORIGliiALStGNED BY:

CUP. (iS J. CGVifGILL

Curtis J. Cowgill, Chief

Projects Branch No.

1

Division of Reactor Projects

Enclosure:

NRC Region I Combined Inspection Report Nos. 50-220/94-05 and

50-410/94-05

~mr rgb

940516

5160068

940506

PDR

ADOCK 05000220

PDR

Mr. B. Ralph Sylvia

Your cooperation with us is appreciated.

Sincerely,

Cutis J. Cowgill, Chief

Projects Branch No.

1

Division of Reactor Projects

Enclosure:

NRC Region I Combined Inspection Report Nos. 50-220/94-05 and

50-410/94-05

cc w/encl:

L. Ston, Vice President - Nuclear Generation

C. Terry, Vice President - Nuclear Engineering

M. McCormick, Vice President,

Safety Assessment & Support

R. Abbott, Unit 1 Plant Manager

J. Mueller, Unit 2 Plant Manager

D. Greene, Manager, Licensing

J. Warden, New York Consumer Protection Branch

G. Wilson, Senior Attorney

M. Wetterhahn, Winston and Strawn

Director, Energy &Water Division, Department of Public Service, State of New York

C. Donaldson, Esquire, Assistant Attorney General, New York Department of Law

K. Abraham, PAO (2) AllInspection Reports

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New York, SLO Designee

1

MAY

6 I994

Mr. B. Ralph Sylvia

bcc w/encl:

Region I Docket Room (with concurrences)

C. Cowgill, DRP

L. Nicholson, DRP

R. Fuhrmeister, DRP

B. Norris - Nine Mile Point

R. Capra, NRR

J. Menning, NRR

D. Brinkman, NRR

bcc w/encl: (VIAE-MAIL)

M. Shannon, NRR (MXS1)

V. McCree, OEDO (VMM)

RI:DRP

BNorris

04/29/94

RI:

L

lson

05l5/94

RI:DRP

CCo gi

05/ /94

OFFICIALRECORD COPY

a:IR940505