, February 18, 1992 Docket Nos.
50-220 and 50-410 Hr.
B. Ralph Sylvia Executive Vice President, Nuclear Niagara Mohawk Power Corporation 301 Plainfield Road
- Syracuse, New York 13211
Dear Nr. Sylvia:
DISTRIBUTION:
~'Docket.File':
PDI-1 Reading JCalvo CVogan RLaura ACRS (10)
Plant File
- JNorberg, 7/E/23 NRC 8 Local PDRs SVarga RACapra DBrinkman OGC CCowgill AGody, Jr.,13/E/21 TScarbrough, 7/E/23
SUBJECT:
SAFETY-RELATED HOTOR-OPERATED VALVE TESTING AND SURVEILLANCE AT NINE MILE POINT NUCLEAR STATION UNITS 1
AND 2 (TAC NOS.
N75686 AND N75687)
By letter dated February 5,
- 1992, Niagara Mohawk Power Corporation (NHPC) supplemented its October 10,
- 1990, response to Generic Letter (GL) 89-10, "Safety-Related Motor-Operated Valve Testing and Surveillance," for Nine Mile Point Nuclear Station Units 1 and 2.
The October 10, 1990, letter did not commit to fully meet the recommendations and schedule provided in GL 89-10;
- however, the February 5,
1992, letter states that it is NHPC's intention to meet the schedule and recommendations of GL 89-10 as described in the Nine Mile Point Unit 1 and Unit 2 HOV Program Plans.
Therefore, we consider NHPC's response to GL 89-10, including Supplements 1 and 2, complete and TAC Nos.
H75686 and M75687 are closed.
Our review of NHPC's responses to GL 89-10, Supplement 3
(TAC Nos.
H77787 and N77788), is continuing and we will notify you when that review is complete.
If you have any questions regarding this action, please contact Donald S.
Brinkman (Project Manager for Unit 1) or Richard A. Laura (Acting Project Manager for Unit 2) at (301) 504-1409 or (301) 504-1424, respectively.
Sincerely, Original Signed By Daniel McDonald for Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects I/II Office of Reactor Regulation cc:
See next page OFFICE LA:PDI-1 PH: PD I-1 PH:PDI-1 HAHE CVo an Cg)
DBrinkman:avl RLaura Ca ra DATE
/lS 92 X (F/92
- 3. /g/92 92 OFFICIAL RECORD COPY FILENAME: A:iNH75686. LTR 92022b0273 5000220 g 9202i8, PDR ADOCK 0 PDR P
III~!7g F'i)~ Pi,; )PQP ggII V pl
r t
'h
~G gp,8 REcc Wp0 0
. ~
O P
Yp
+**++
UNITED STATES NUCLEAR R EG ULATORY COMMISS ION WASHINGTON, D. C. 20555 February 18, 1992 Docket Nos.
50-220 and 50-410 Hr. B. Ralph Sylvia Executive Vice President, Nuclear Niagara Mohawk Power Corporation 301 Plainfield Road
- Syracuse, New York 13211
Dear Hr. Sylvia:
SUBJECT:
SAFETY-RELATED MOTOR-OPERATED VALVE TESTING AND SURVEILLANCE AT NINE MILE POINT NUCLEAR STATION UNITS 1
AND 2 (TAC NOS.
H75686 AND H75687)
By letter dated February 5,
- 1992, Niagara Mohawk Power Corporation (NHPC) supplemented its October 10,
- 1990, response to Generic Letter (GL) 89-10, "Safety-Related Motor-Operated Valve Testing and Surveillance," for Nine Mile Point Nuclear Station Units 1 and 2.
The October 10, 1990, letter did not commit to fully meet the recommendations and schedule provided in GL 89-10;
- however, the February 5,
1992, letter states that it is NHPC's intention to meet the schedule and recommendations of GL 89-10 as described in the Nine Mile Point Unit 1 and Unit 2 HOV Program Plans.
Therefore, we consider NMPC's response to GL 89-10, including Supplements 1 and 2, complete and TAC Nos.
M75686 and M75687 are closed.
Our review of NHPC's responses to GL 89-10, Supplement 3
(TAC Nos.
H77787 and H77788), is continuing and we will notify you when that review is complete.
If you have any questions regarding this action, please contact Donald S.
Brinkman (Project Manager for Unit 1) or Richard A. Laura (Acting Project Manager for Unit 2) at (301) 504-1409 or (301) 504-1424, respectively.
Sincerely, cc:
See next page W Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects - I/II Office of Reactor Regulation
,4r.
B. Ralph Sylvia Niagara Hohawk Power Corporation Nine Mile Point Nuclear Station Unit Nos.
1 and 2
CC:
Mark J. Wetterhahn, Esquire Winston
& Strawn 1400 L Street, NW Washington, DC 20005-3502 Supervisor Town of Scriba Route 8, Box 382
- Oswego, New York 13126 Hr. Joseph F. Firlit Vice President - Nuclear Generation Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Post Office Box 32
- Lycoming, New York 13093 Resident Inspector U.
S. Nuclear Regulatory Commission Post Office Box 126
- Lycoming, New York 13093 Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
- Syracuse, New York 13202 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Hs.
Donna Ross New York State Energy Office 2 Empire State Plaza 16th Floor
- Albany, New York 12223 Hr. Kim Dahlberg Unit 1 Station Superintendent Nine Nile Point Nuclear Station Post Office Box 32
- Lycoming, New York 13093 Hr. Hartin J.
HcCormick Jr.
Plant Manager, Unit 2 Nine Mile Point Nuclear Station Post Office Box 32
- Lycoming, New York 13093 Charles Donaldson, Esquire Assistant Attorney General New York Department of'Law 120 Broadway New York, New York 10271 Hr. Paul D.
Eddy State of New York Department of Public Service Power Division, System Operations 3 Empire State Plaza
- Albany, New York 12223 Hr. David K. Greene Manager Licensing Niagara Mohawk Power Company 301 Plainfield Road
- Syracuse, New York 13212 Hr. Richard Goldsmith Syracuse University College of Law E. I. White Hall Campus
- Syracuse, New York 12223 Hr. Richard M. Kessel Chair and Executive Director State Consumer Protection Board 99 Washington Avenue
- Albany, New York 12210
0