ML17055D764
| ML17055D764 | |
| Person / Time | |
|---|---|
| Site: | Nine Mile Point |
| Issue date: | 04/11/1988 |
| From: | Capra R Office of Nuclear Reactor Regulation |
| To: | |
| Shared Package | |
| ML17055D765 | List: |
| References | |
| TAC-67173, NUDOCS 8804190076 | |
| Download: ML17055D764 (8) | |
Text
g~S (4
~4 Cy RfCy Wp O~
AnO Cy
~O
- <<~
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 NIAGARA MOHAWK POWER CORPORATION DOCKET NO. 50-410 NINE MILE POINT NUCLEAR STATION, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 4 License No.
NPF-69 1.
The Nuclear Regulatory Comission (the Commission) has found that:
A.
The application for amendment by Niagara Mohawk Power Corporation (the licensee) dated February 3, 1988, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; R.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the CoIImIission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No.
NPF-69 is hereby amended to read as follows:
8804i90076 8804ii PDR ADOCK- 050004i0 PDR
(2)
Technical S ecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A-and the Environmental Protection Plan contained in Appendix B, both of which are attached
- hereto, as revised through Amendment No.
4 are hereby incorporated into this license.
Niagara Mohawk Power Corporation shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
3.
This license amendment is effective as of the date of its issuance, and is to be implemented within 30 days.
FOR THE NUCLEAR REGULATORY COMMISSION ReC~W cL C~
Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects, I/II
Attachment:
Changes to the Technical Specifications Date of Issuance:
April ll, 1988
I'
ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO.
TO FACILITY OPERATING LICENSE NO.
NPF-69 DOCKET NO. 50-410 Revise Appendix A as follows:
Remove Pa e
3/4 3-19 Insert Pa e
3/3 3-19
~.
~
l
TABLE 3.3.2-2 (Continued)
ISOLATION ACTUATION INSTRUHENTATION SETPOINTS TRIP FUNCTION 2.
RCIC Isolation Si nals (Continued) d.
,RCIC Turbine Exhaust Diaphragm Pressure High e.
RCIC Equipment Area T'emperature - High f.
RCIC Steam Line Tunnel Temperature High g.
Hanual Isolation Push Button fRCIC]
h.
Orywell Pressure High i.
RHR/RCIC Steam Flow High 3.
Secondar Containment Isolation Si nals a.
Reactor Building Above the Refuel Floor Exhaust Radiation High b.
Reactor Bui lding Below the Refuel Floor Exhaust Radiation High TRIP SETPOINT 10 psig
< 135'F
< 135'F NA
< 1.68 psig
< 37.4 in.H20
< 2.36 x 10-3 pCi/cc
< 2.36 x 10-3 p Ci/cc ALLOHABLE VALUE
< 20 psig
< 140.5'F 140.5'F NA
< 1.88 psig
< 40.73 in.
H20
< 2.46 x 10-3 PCi/cc
< 2.46 x 10-3 pCi/cc