ML17055D670

From kanterella
Jump to navigation Jump to search
EN-88-019:on 880314,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $100,000 on or About 880314,based on Operation of Plant W/O Dispositioning Certain Weld Flaw Indications Between June 1986 & Sept 1987
ML17055D670
Person / Time
Site: Nine Mile Point 
Issue date: 03/09/1988
From: Lieberman J, Wong H
NRC OFFICE OF ENFORCEMENT (OE)
To:
References
EA-87-224, EN-88-019, EN-88-19, NUDOCS 8803160182
Download: ML17055D670 (2)


Text

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8803160182 DOC.DATE: 88/03/09 NOTARIZED: NO FACIL:50-220 Nine Mile Point Nuclear Station, Unit 1, Niagara Powe AUTH.NAME AUTHOR AFFILIATION WONG,H.

Ofc of Enforcement (Post 870413)

LIEBERMAN,J.

Ofc of Enforcement (Post 870413)

RECIP.NAME RECIPIENT AFFILIATION DOCKET g

05000220

SUBJECT:

EN-88-019:on 880314,notice of proposed imposition of civil penalty in amount of $ 100,000 to be issued to licensee.

based on DISTRIBUTION CODE: IE33D COPIES RECEIVED:LTR J ENCL ~ 'SINE:

TITLE: Enforcement Notice (EN)

NOTES R

RECIPIENT ID CODE/NAME INTERNAL: AEOD/DOA DEDRO NRR/DREP/EPB10D OE FILE 01 02 EXTERNAL: LPDR NSIC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME AEOD/DSP/TPAB NRR/DOEA/EAB11E NRR/PMAS/ILRB12 OE LIEBERMAN,J RGN2/DRSS/EPRPB NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 D

8 S

A TOTAL NUMBER OF COPIES REQUIRED:

LTTR 13 ENCL

March 9, 1988 EN 88-19 OFFICE OF ENFORCEMENT NOTIFICATION EMENT ACTION Licensee:

Nfagar a Mohawk Power Corporation (EA 87-224)

Nine Nile. Point Unit 1

Docket No.

50-220

~Sub'ect:

PROPOSED INPOSITION OF CIVIL PENALTY - $ 100,000 Thfs fs to inform the Commission that a Notice of Vfolatfon.andpPjiposed Imposition of Civil Penalty fn the amount of One Hundred Thousand-Dollars

($ 100,000) will be issued on or about March 14, 1988 to Niagara Mohawk Power Corporatfon.

This action fs based on operation of the plant. between+Dune 1986 and September 1987 without dfspositfonfng certain weld flaW;indications which were identified by the inservice inspections conducted durfng the 1986 refueling outage.

The licensee failed to take advantage of subsequent opportunities to identify and correct these deficiencies.

In addition, the appropriate operations personnel were not notified when the existence of these nonconformances was identified.

The base cfvfl penalty was increased by 100 percent because of the licensee's prior poor performance fn the area of concern.

It should be noted that the licensee has not been specifically informed of the enforcement action.

The schedule of issuance and notification fs:

Mailing of Notice Telephone Notification of Licensee The State of New York will be notified.

March 14, 1988 March 14, 1988 The licensee has thirty days from the date of the Notice fn which to respond.

Following NRC evaluation of the response, the civil penalty may be remitted, mitigated, or imposed by Order.

Contact:

H. Wong, OE, 23281 J.

Lfeberman, OE, 20741 Distribution H Street K'<'5 Chairman rect Coen.

Roberts Comm. Berntha1 Comm. Carr Comm.

Rogers SECY ACRS CA OGC GPA MNBB %~(

EDO DEDRO RM AEOD PA NRR OE NMSS OGC OI SP OSP Regional Offices RI ~A%

RIV RII ~4 RV ~IM RIII~

MAIL ADM: Doc. Mgt. Br.

PDR RES

'IA PRELIMINARY INFORMATION -

NOT FOR PUBLIC DISCLOSURE UNTIL PUBLICLY ANNOUNCED

, 88t.$ 3j/~(. 182 88($809 F'DR VIE EN-88-Gled DCD