~gg REQy 1p O~

~

Cy O

I

.s ~

't o~

/p ++*<<"

UNITED STATES

~

NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 NIAGARA MOHAWK POWER CORPORATION DOCKET NO. 50-410 NINE MILE POINT NUCLEAR STATION, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.

2 License No. NPF-69 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Niagara Mohawk Power Corporation of New York, Inc. (the licensee) dated November 16, 1987, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance iiith the Commission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-69 is hereby amended to read as follows:

88030S0255'.85pppygp PDR

>DOCK 050 pDR P

V h

(

(2}

Technical S ecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix 8, both of which are attached

hereto, as revised through Amendment No.

2 are hereby incorporated into this license.

Niagara Mohawk Power Corporation shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of the date of its issuance.

Attachment:

Changes to the Technical Specifications FOR THE NUCLEAR REGULATORY COMMISSION

< Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects, I/II Date of Issuance:

February 26, 1988

'F

~$ REOy

~o Cy pO I

p

~

z+

~O

++*<<+

UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 ATTACIIMENT TO LICENSE AMENDMENT AMENDMENT NO.

2 TO FACILITY OPERATING LICENSE NO. NPF-69 DOCKET NO. 50-410 Revise Appendix A as follows:

Remove Pa e

3/4 3-18 Insert Pa e

3/4 3-18

0

< ~

TABLE 3.3.2-2 (Continued)

ISOLATION ACTUATION INSTRUHENTATION SElPOINTS a

C)

-I 4J I

CO CD CL S

CO O

1R11 rUNCriON 1.

P1.imar Containment Isolation Si nals (Continued) i.

RNCU System 1)

~ Flow - High 2) h Floe - High, Timer 3)

Standby Liquid Control, Si.CS, Initiation j.

RHCU Equipment Area Temperature 1)

Pump Room A Temperature High 2)

Pump Room B Temperature High 3)

HX Room Temperature High k.

Reactor Building Pipe Chase I)

Azimuth 180 (Upper),

Temperature - High 2)

Azimuth 180 (Lower), Temperature High 3)

Azimuth 40',

Temperature High l.

Reactor Building Temperature High m.

Hanual Isolation Pushbutton tNSSSS]

2.

RCIC Isolation Si nals a.

RCIC Steam Line Flow High, Timer b.

RCIC Steam Supply Pressure Low c.

RCIC Steam Line Flow - High TRIP SETPOINf

< 150.5 gpm

< 45 sec NA 135'F 150 F

135'F 135'F 135'F 135'F 130.2'F 3 sec 13 sec 75 ps1a 167 1 in H20 ALLOHABLE VALUE 165.5 gpm

< 47 sec NA 144. 5'1' 159.5 F

140.5'F

< 144.5'F 140.5'F 140.5'F 134'F 13 sec

> 70 psia 175.6 in. H20

~

I J