UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 NIAGARA MOHAWK POWER CORPORATION DOCKET NO. 50-220 NINE MILE POINT NIICLEAR STATION UNIT NO.
1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.
90 License No.
DPR-63 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Niagara Mohawk Power Corporation (the licensee) dated September 15, 1986, complies with the'standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act; and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized hy this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and 2.
E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-63 is hereby amended to read as follows'.
8701130082 Bggggp~
- DOCK 05000220 P
- PDR,
~ <
(2)
Technical S eci ficati ons The Technical Specifications contained in Appendix A, as revised through Amendment No. 90, are hereby incorporated in the license.
The licensee shall operate
-the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR TH NUCLEAR REGULA RY QMMISSION Joh A. Zwolinski, Director BWR Project Directorate
.5'1 Division of BWR Licensing
Attachment:
Changes to the Technical Specifications Date of Issuance:
December 29, 1986
\\~... I
~ '
u,
~
~
'- y 0='
~ '
Lrlg V wgw
)s
~;,i
~
'TTACRYIENT TO LICENSE AMENDMENT NO.
90 FACILITY OPERATING LICENSE NO.
DPR-63 DOCKET NO. 50-220 Revise the Appendix A Technical Specifications by removina the pages identified below and inserting the attached pages.
The revised pages are identified by the captioned amendment number and contain marginal lines
'ndicating the area of change.
REMOVE 246 250 251 INSERT 246 250 251
Facilit Staff (Cont'd) e.
A licensed Senior Reactor Operator shall be required in the Control Room during power operations, hot
- shutdown, and when the emergency plan is activated.
This may be the Station Shift Supervisor-Nuclear or the Assistant Station Shift Supervisor-Nuclear or another Senior Reactor Operator during power operations or hot shutdown.
Hhen the emergency plan is activated during normal operations or hot shutdown, the
'Assistant Station Shift Supervisor-Nuclear becomes the Shift Technical Advisor and the Station Shift Supervisor-Nuclear is restricted to the control room until an additional licensed Senior Reactor Operator arrives.
f.
A licensed Senior Reactor Operator shall be responsible for all movement of new and irradiated fuel within the site boundary.
All core alterations shall be directly supervised by a licensed senior reactor operator uho has no other concurrent responsib> 1tt)es dur>ng thts operat)on.
A L> censed Operator et 11 b required to manipulate the controls of all fuel handling equipment except movement of new fuel from receipt through dry storage.
All fuel moves within the core shall be directly monitored by a member of the reactor analyst group.
g.
A Fire Brigade of five (5) members* shall be maintained on site as defined by 5.1 at all times.
h.
Administrative procedures shall be developed and implemented to limit the working hours of facility staff who perform safety-related functions; e.g.,
licensed Senior Operators, licensed Operators, health physicists, auxiliary operators and key maintenance personnel.
Adequate shift coverage shall be maintained without routine heavy use of overtime.
The objective shall be to have operating personnel work a normal 8-hour day, 40-hour week awhile the facility is operating.
However, in the event that unforeseen problems require substantial amounts of overtime to be used, or during extended periods of shutdown for refueling, ma)or maintenance or ma)or plant modifications on a temporary basis, the following guidelines shall be followed:
- The Radiation Protection qualified Individual and Fire Brigade composition may be less than the minimum requirements for
- a period of time not to exceed two hours in order to accommodate unexpected
- absence, provided i(mediate action is taken to fill the required positions.
Amendment No. 5$ p 88, 90 246
Table 6.2-1 HINIHUH SHIFT CREH COMPOSITION( ) <6) license Senior Operator Operator Unlicensed(2)
Normal 0 eration Shutdown Condition l(5)
Operation(3)
H/0 Process Com uter Reactor
~Startu s
Asst. Station Shift Supervisor (Shift Technical Advisor Fgnctlon)
(Senior Operator License)(>>
Notes:
(1)
At any one time, more licensed or unlicensed operating people could be present for maintenance,
- repairs, refuel
- outages, etc.
(2)
Those operating personnel not holding an "Operator" or "Senior Operator" License.
(3)
For operation longer than eight hours without process computer.
(4)
Hot shutdown condition only.
(S)
An additional senior reactor operator. who has no other concurrent responsibilities. shall supervise all core alterations.
(6)
The Shift Crew Composition may be one less than the minimum requirements of Table 6.2-1 for a period of time not to exceed two hours in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the Shift Crew Composition to within the minimum requirements of Table 6.2-1.
This provision does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.
(7)
The Assistant Station Shift Supervisor performs the Shift Technical Advisor function during normal operations or hot shutdown and shall hold a senior reactor operator license.
Normally the Assistant Station Shift Supervisor is a combined Assistant Station Shift Supervisor/Shift Technical Advisor; however, there may be instances when a shift may be staffed by two Senior Reactor Operators plus a dedicated Shift Technical Advisor.
~,
~:.
Amendment No. 55, 90 250
~
~
6.3 Faci lit Staff ual ifi cations 6.3.1 Each member of the unit staff shall meet or exceed the minimum qualifications of ANSI N18.1-1971 for comparable positions, except for the Shift Technical Advisor who shall have a bachelor's degree in a physical science or engineering or a professional engineer license issued by examination and shall have received specific training in plant design, and response and analysis of the plant for transients and accidents 6.4
~Tra)nln 6.4.1 A retraining and replacement training program for the facility staff shall be maintained under the direction of the Superintendent-Training Nuclear and shall meet or exceed the requirements and recotenendations of Section 5.5 of ANSI N18.1-1971 and Appendix "A" of 10CFR Part 55 6.4.2 A training program for the Fire Brigade shall be maintained under the direction of the Superintendent-Training Nuclear and Supervisor-Fire Protection, Nuclear and shall meet or. exceed the requirements of Ap di R t 10CFR50.
6.5 Review and Audit 6.5.1 Site 0 erations Review Committee (SORC)
Function 6.5. 1. 1 The Site Operations Review Committee shall function to advise the General Superintendent-Nuclear Generation on all matters related to nuclear safety Com sition P
6.5.1.2 The'ite Operations Review Coenittee shall be composed of the Chairman:
General Superintendent Nuclear Generation Hember:
Station Superintendent Nuclear Generation Hember:
Technical Superintendent Nuclear Generation Member:
Superintendent Technical Services - Nuclear Hember:
Site Superintendent Maintenance - Nuclear Member:
Supervisor Instrument and Control - Nuclear Hember:
Superintendent Chemistry and Radiation Management Amendment No. 6S, gp
~