U.S.
NUCLEAR REGULATORY COMMISSION
REGION I
Report
No.
50-410/86-43
Docket No.
50-410
License
No.
Category
B
Licensee:
Nia ara
Mohawk Power Cor oration
300 Erie Boulevard
West
S racuse
13202
Facility Name:
Nine Mile Point Nuclear Station
Unit 2
Inspection At:
Scriba
Inspection
Conducted:
Jul
28
1986
Au ust
1
1986
Inspectors:
R.
.
cBre
,
Reac
r Engineer
date
Approved by:
J
. Wiggins
rocesses
hief, Materials
and
ion,
EB,
date
Ins ection
Summar
Ins ection
on Jul
28 - Au ust
1
1986
Ins ection
Re ort
Number 50-410/86-43
~AI: I
I
.
I
I
II
IR
Bulletins and licensee
action
on previous inspection findings.
Results:
No violations were identified.
I
82P
R
ADQcg
p happ
'R
),
'I
-I
DETAILS
1.0
Persons
Contacted
Nia ara
Mohawk Power Cor oration
- G. Afflerbach, Start-up
Manager
~ S. Agarwal, Special
Projects
~ J.
Conway,
Power Ascension
Manager
~
W. Hansen,
Manager Nuclear Quality Assurance
Operations
~ T. Lee, Special
Projects
~ R.
Rao, Project Engineering
- M. Ray,
Manager - Special
Projects
" I. Weakley,
Special
Projects
Stone
and Webster
En ineerin
Cor oration
" T. Arrington, Resident
Manager
" J.
Drake Jr., Stsrtup Special
Projects
Supervisor
" T. Farrell, Assistant Project Engineer
- C. Terry, Project guality Assurance
Manager
U.S. Nuclear
~Re ula<;or~Commission
~
W. Cook, Senior Resident
Inspector
" W. Schmidt,
Resident
Inspector
2.0
Licensee Action on Previous
Ins ection Findin
s
(Closed)
IE Bulletin (79-BU-02):
Pipe Support
Base Plate
Designs
Using
Concrete
Expansion
Anchor Bolts.
The Bulletin was issued to address
problems at nuclear
plants regarding
concrete
anchor bolts.
The inspector
reviewed the licensee's
response
to the Bulletin and ver-
ified, by reviewing documentation,
gC records,
and by measuring
and exam-
ination of selected
installed bolts, that the actions required
by the
Bulletin were met and that the bolt marking system accurately identified
the bolt length.
Based
on the above, this item is considered
closed.
(Closed) Violation (410/86-13-03):
Pipe supports with no measurable
gap.
The
NRC found two Scram Discharge
supports,
lA and
11A, had
no
measurable
gap.
The licensee's
response
to the violation reported that
a
surveillance
performed
by
SWEC identified a third support,
18B, with a
similar problem.
The licensee further reported that the three
supports
were repaired
and the deficient gaps
were corrected.
C
O
The inspector
reviewed the licensee's
response
to the violation,
gC re-
cords
and,
in addition,
independently
measured
the
gap in each of the
three
supports
to ascertain
that the repairs
were effective.
He found
that the originally deficient gaps
were properly repaired
and meet appli-
cable
gap requirements.
Based
on the above this item is considered
closed.
(Closed) Violation (410/86-13-01):
Rigging of equipment to safety related
components.
The
NRC finding involved two instances
of equipment being
improperly rigged to safety related
components
in the plant.
The inspec-
tor verified, through
a review of records,
that the corrective
and pre-
ventive actions
by the licensee
were carried out.
He found that the re-
quired evaluation
was made,
the applicable
procedure
was revised
and per-
sonnel
were issued
reminders
regarding rigging requirements
at the plant.
Based
on the
above this item is considered
closed.
(Closed)
Unresolved
Item (410/86-13-04):
Absence of damper counterweights
on backdraft
2HVC 'OMP 63.
The inspector
reviewed licensee
records
which indicate that .he damper
operates
satisfactorily with the counterweight
removed.
Included in the
inspector's
review was
a letter dated
Nay 27,
1986,
from the equipment
manufacturer,
which states
that in small dampers,
usually those
less than
one square
foot in surface
area,
the counterweight is not absolutely
ne-
cessary
to assist
in blade closure.
The damper in question is 6" x 6" or
'4 square foot in surface
area.
Based
on the
above this item is considered
closed.
(Closed) Violation (410/86-08-01):
Drawing in use without having the re-
quired verification stamp.
The inspector
reviewed licensee
records which
indicated that the drawing in question
was found to be the latest issue
and correct for use.
Additionally gA surveillances
found
no further
examples of unstamped
drawings in use in the plant.
The inspector
found
that the appropriate
personnel
were reminded of the requi rement for draw-
ings to be properly stamped,
initialed and dated prior to use.
Based
on the above this item is closed.
3.0
Exit Interview
The inspector
met with licensee
representatives
(denoted
in paragraph
1)
at the conclusion of the inspection
on August 1,
1986.
The inspector
summarized
the purpose
and the
scope of the inspection
and the findings.
At no time during this inspection
was written material
provided by the
inspector to the licensee.