Amend 50 to License DPR-63,approving Recirculation Sys Piping Replacement Program
ML17053D335
Person / Time
Site: Nine Mile Point 
Issue date: 10/15/1982
From: Vassallo D
Office of Nuclear Reactor Regulation
To:
Shared Package
ML17053D334 List:
References
NUDOCS 8211060409
Download: ML17053D335 (4)


Text

P'Ii RE0I Cy UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 NIAGARA tQHAWK POWER CORPORATION DOCKET NO. 50-220 NINE t1ILE POINT NUCLEAR STATION UNIT NO.

1 At1ENDMENT TO FACILITY OPERATING LICENSE Amendment No.

50 License No. DPR-63 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

B.

C.

D.

The filings by Niagara Mohawk Power Corporation (the licensee) dated August 6, 16, 26,

1982, September 27, 1982 and October 6,

1982 comply with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's regulations set forth in 10 CFR Chapter I; The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's xegulations; The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and The issuance of this amendment i s in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, Facility Operating License No.

DPR-63 is hereby amended by replacing paragraph 2.D.(6) in its entir ety with the following:

\\

2,D(6)

Recirculation S stem and Safe-end Re lacement The recirculation system and safe-end replacement program including the cutting and welding of the replacement components and the dose mitigation program (ALARA) is approved, subject to the following conditions:

a.

The licensee shall complete the recirculation piping stress reanalysis prior to restart of Nine Mile Point Nuclear Power Station, Unit No. l.

The results of this analysis for selected representative portions of the recirculation system shall be submitted to the NRC prior to restart of the facility.

, 82ii060409 82iOi5 PDR ADOCK 05000220 P

C r

b.

c ~

All fuel and control rods shall be removed from the reactor pressure vessel and stored in the spent fuel pool during the period that work on the safe-end and recirculation system replacement program is in progress."

The licensee shall update the collective occupational dose estimate weekly. If the 'updated estimate exceeds the 1908 person-rem estimate by more than 10Ã, the licensee shall provide a revised

estimate, including the reasons for such changes, to the NRC within 15 days of determination.

d.

Progress reports shall be provided at 90-day intervals from June 30, 1982 and due 30 days after close of the interval, with a final report within 60 days after completion of the repair.

These reports will conclude; (1) a summary of the occupational dose received to date by major task, and (2) a comparison of estimated doses with the doses actually received.

3.

Thais license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Date of Issuance:

October 15, 1982 Domenic B. Vassallo, Chief Operating Reactor s Branch 82 Division of Licensing