LR-N17-0034, Salem Generating Station, Units 1 & 2, Revision 29 to Updated Final Safety Analysis Report, Figures 11.4-1 to 11.4-9

From kanterella
(Redirected from ML17046A506)
Jump to navigation Jump to search
Salem Generating Station, Units 1 & 2, Revision 29 to Updated Final Safety Analysis Report, Figures 11.4-1 to 11.4-9
ML17046A506
Person / Time
Site: Salem  PSEG icon.png
Issue date: 01/30/2017
From:
Public Service Enterprise Group
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17046A230 List: ... further results
References
LR-N17-0034
Download: ML17046A506 (14)


Text

FIELD -CONTROL FUNCTIONS CONTROL ROOM AREA PLANT COMPUTER 1---------1 L DC AL 1----+------1 REM 0 T E DETECTOR MONITOR MONITOR TYPICAL RADIATION MONITORING STRUCTURE ANNUNCIATOR PSEG NUCLEAR LLC SALEM GENERATING STAT ION UNIT NOa 2 OVERALL RADIATION MONITORING SYSTEM MAKEUP Updated FSAR Sheet 1 of 1 REVISION 27, NOVEMBER 25,2013 F 1 g a 11 a 4 -1 AIR PARTICULATE 8c GAS MONITOR FROM CONTAINMENT I ALARM ANNUNCIATOR ISOLATION/ALARM SIGNALS -------------. MOVING FILTER PARTICULATE ASSEMBLY SAMPLE SKID CONTROLS FIXED FIL TERt--------t IODINE AND NOBLE GAS DETECTOR ASSEMBLY TO CONTAINMENT LOCAL MICROPROCESSOR AND DISPLAY PSEG Nuclear. LLC SALEM NUCLEAR GENERATING STATION TO P250 TO SPDS CONTROL ROOM METERS .,__-....... lRllA I 0 ...... I ..__ _ ___. CONTROL ROOM EQUIPMENT I 0 t------t DISPLAY ....... ....... FAIL ANNUNCIATOR ..__ ....... I 1R12B I 0 ...... l CONTROL ROOM ALARM LAMP Revision 19, Nov.1q, 2001 Solem Nuclear Station UNIT NO.1 AIR PARTICULA E IODINE AND GAS MONITOR (TYPICAL) Updated FSAR Figure 11.4-2 CO 2000 PSEG Nuc le<r, LLC. All Rights Reserved.

Air { Sample Containment or Plant Vent Particulate Filter Mech. Iodine Filter Sampler Gas Sampler --------, I I Detector I I I I t l I J l J 1 I *-------------l ' I / -0 Alarm / ' / ' -lwl Fail / ' Checksource / I ' X.XXXE:tyy 2-R11Af 12A, B Control Room Display Control Functions (Tables 11.2-7) PUBLIC SERVICE ELECTRIC AND GAS COMPANY SALEM NUCLEAR GENERATING STATION Unit No. 2 Air Particulate, Iodine and Gas Monitor {Typical) Updated FSAR Revision 16 Figure 11.4-3, Sheet 1 of 1 January 31, 1998


1 I I I I I I I I I I I I I I I I EFFLUENT IN I I I I I I I I I I I I I I I I I I I I DETECTOR I I I I I I I I I I I SAMPLER I I I I I ' I I EFFLUENT OUT LIQUID PROCESS MONITOR <TYPICAL> CONTROL ROOM ANNUNCIATOR CHECK SOURCE HIGH RADIATION VISUAL ALARM RELAYS CONTROL EQUIP. ROOM READ OUT MODULE RECORDER <CONTROL EOUIP. RM.1 INTERLOCKS <IF SHOWN IN THE TABLE> CONTROL ROOM READ OUT <METER> WARNING ALARM CHANNEL FAILURE ALARM I I I I I I I I I I I I I I I I I I I ------------------------------2"010" PSEG Nuclear, LLC Solem Nuclear Generating Station UNIT NO.1 LIQUID MONITOR <TYPICAL> SALEM NUCLEAR GENERATING STATION ted fSAR SHEET 1 Of 4 figure 11.4-4 2000 PSEG Nttle<r. LtC. All Ri4Jts Reserved.

      • HIGH _RAD AUDIBLE ALARM DIGITAL LIQUID -PROCESS MONITOR (TYPICAL> HIGH RAD VISUAL ALARM 0ALERT HIGH RAD VISUAL
  • ALARM . IN CONT.ROOM COMPUTER CONTROL ROOM ANNUNCIATOR CONTROL INTERLOCKS ROOM (IF SHOWN INDICATION IN THE <METER) TABLE> . 0000 HIGH ALERT NORMAL FAIL I DISPLAY! 0FAIL 0NORMAL .* SAMPLE a....,;._ __ L_O_CA_L_M_ON_I ...... TO'l""""'R---,r-' iS SAMPLE l IN I DISPLAYI REMOTE MONITOR I I I L_ SAMPLER . PSEG Nuclear, LLC I CHECK SOURCE y ___ __, SALEM NUCLEAR GENERATING STATION CONTROL EQUIPMENT ROOM ReviSIOn 21, Dec. 6, Salem Nuclear. Generating Station UNIT NO.1 LIQUID UONITOR CTYPICAL) Updated FSAR . SHEET 2 Figure 11.4-4
  • DIGITAL LIQUID PROCESS MONITOR <TYPICAL) HIGH RAD AUDIBLE ALARM HIGH RAD VISUAL ALARM I'DISPLAYI + LOCAL MONITOR CONO".OFF GAS AIR FLOW HIGH RAD VISUAL ALARM IN CONT.ROOM COMPUTER CONTROL ROOM ANNUNCIATOR CONTROL INTERLOCKS . ROOM <IF SHOWN INDICATION IN THE CMETER> TABLE> 0 0 HIGH ALERT NORMAL FAIL I DISPLAYI REMOTE MONITOR CONTROL EQUIPMENT ROOM SAMPLE SAMPLE IN !; L-SAMPLER PSEG Nuclear. LLC CHECK SOURCE SALEM NUCLEAR GENERATING STATJON y Rev1s1on 21, Dec. 6, Solem Nuclear Generating Station UNfT NO.1 COND. AIR EJECT RAD MONITOR 1R15 (TY Updated FSAR SHEET 3 Figure 11.4-4 Reserved.

LlQUlD PROCESS MONlTOR HlOH RAO AUDIBLE HIGH RAD VISUAL ALARM [ DlSPC§yJ l.OCAL MONit: OR HlOH RAD AUDIBLE At..AAM 1R13A

  • HIGH RAD VISUAL ALARM [QJ.SPLAX) LOCAL MONITOR 1R138 1R13A & B COMPU7ER CONTROL *ROOM ANNUNCIATOR REMOTE MONlTOR CONTROL EQUt?MEtJT ROOM PSEG NUCLEAR LLC SALEM GENERATING STAT ION UNIT NOa 1 LIQUID MONITOR 1R13 A & B Updated FSAR Sheet 4 REVISION 27, NOVEMBER 25,2013 F 19a lla4 -4 DIGITAL LIQUID -PROCESS MONITOR tTYPICALl HIGH .. RAD HIGH . RAD AUDIBLE ** VISUAL ALARM ALARM COMPUTER* CONTROL ROOM ANNUNCIATOR m w m I DISPLAY! 0FAIL HIGH ALERT NORMAL FAIL 1-----.,--i----l I DISPLAY! r SAMPLE ** LOCAL MONITOR SAMPLE I 1$ _L j_* f; : fDErl r:m : REMOTE MONITOR CONTROL EQUIPMENT ROOM I CHECK I' l --' SAMPLER SOURCE I I '---------""---_J I Note: 2R19A, B, 0 Share The Same Remote Aeld Unlt and Have No Connections to the Centrar Processing Unit Rev1s1on 269 2L 2012 PUBUC SERVlC£ ELECTRIC AND GAS CWPAHV SALEM NUCLEAR GENERATING STATION UNIT NO. 2 LIQUID MONITOR (TYPICAL) Updated FSAR ,Sheet 1 of 2 FIQ ure 11.4*5 HIGH RAD AUDIBLE HIGH RAD VISUAL ALARM DJGIT AL LIQUID PROCESS MONiTOR 2R13A & B mALEAT WFAIL mNORMAL LOCAL MONITOR HIGH RAO AUDIBLt: ALARM 1cW PIPE 12 HIGH RAO VISUAL ALARM [tjj§f!LAjl mFAIL LOCAL MONITOR 1CW PIPE 11 COMPUTER CONTROL ROOM . ANNUNCIATOR ...__---=i HIGH ALERT NORMAL FAlL 1 oiseceYJ REMOTE CONTROL EQUIPMENT PSEG NUCLEAR LLC SALEM GENERATING STATION UNIT NOa 2 LIQUID MONITOR 2R13A & B Updated FSAR REVISION 27, NOVEMBER 25,2013 Sheet 2 F l9a lla4-5
  • THIS FIGURE HAS BEEN DELETED
  • Revtslon 21, .Dec. 6, 2004 PSEG Nuclear, LLC . Salem Nuclear . Generating . Station UNIT 2 IN-LINE GAS MODEL <TYPICAL> SALEM NUCLEAR GENERATING STATION doted FSAR Figure 11.4-6 CHECK SOURCE HIGH RADIATION AUDIBLE ALARM DETECTOR LOCAL READOUT HIGH RADIATION VISUAL I ALARM PSEG Nuclear, LLC AREA MONITOR <TYPICAL> CONTROL ROOM ANNUNCIATOR HIGH RADIATION VISUAL ALARM CONTROL EQUIP. ROOM READ OUT MODULE RECORDER (CONTROL EQUIP. RM.) INTERLOCKS CIF SHOWN IN THE TABLE) CONTROL ROOM READ OUT <METER> WARNING ALARM Revtston }q, Nov.lq, 2001 Solem Nuclear Generating Station UNJT NO.1 AREA MONITOR (TYPICAL) SALEM NUCLEAR GENERATING STATION Updated FSAR SHEET 1 OF 2 Figure 11.4-7 © 2000 PS£G u\oor. llt. Rights Reservoo.

DIGITAL AREA MONITOR CTYPICAL) HIGH RAD AUDIBLE ALARM HIGH RAD VISUAL ALARM w:ALERT HIGH RAD VISUAL ALARM IN CONT.ROOM COMPUTER CONTROL ROOM ANNUNCIATOR CONTROL INTERLOCKS ROOM CIF SHOWN INDICATION IN THE CMETER> TABLE> w:w:mw: HIGH ALERT NORMAL FAIL I DISPLAY! w:FAIL LOCAL MONITOR DETECTOR CHECK SOURCE APPLICABLE RMS CHANNELS: 1R2,1R3,1R4,1R5,1R6A,1R7,1R9,1R10A PSEG Nuclear, LLC SALEM NUCLEAR GENERATING STATION I DISPLAYI REMOTE MONITOR CONTROL EQUIPMENT ROOM Rev1s1on 19, Nov.l9, 2001 Salem Nuclear Generating Station UNIT NO.1 AREA MONITOR (TYPICAL> Updated FSAR SHEET 2 OF 2 Figure 11.4-7 CD 2000 PSE G Nuc l ecr. ll C. A II Rights Reserved.

. c e t e c t c r [ TO REMOTE UNIT =rnr Alarm . K High RAcllllon Audib!a Alarm I ' -lY]VM J ' Radla!ion -(mFd , . Visuaf.&m ' .. m CMcbcurct ' I I X .. I f4-POWER SUPPLY .---, I I LOCAL I "* L _.,._ CONTROL FIELD " FUNCTIONS/ UNIT 1 r

  • I INTERLOCKS c. ... J. (AS SHOWN IN TABLE 11-2 .. -7) PSEG NUCLEAR LLC SALEM GENERATING STAT ION UNIT NOa 2 AREA MONITOR (TYPICAL) Updated FSAR Sheet 1 of 1 REVISION 27, NOVEMBER 25,2013 F 1 ga 11 a 4-8
  • UNIT 1 ClRPl> CONTROL ROOM AREA RATE METER UNITt (2> CONTROL EQUIPMENT ROOM CPM CPM CHANNEL 1 ' / D ALARM / ' ' / 0.WARN / ' ' / D NORM / ' ----, NOTE: l.CHANNEL 1 INTERLOCKS WITH RESPECTIVE UNITS CONTROL CIRCUITS.CHANNEL 2 INTERLOCKS WITH OPPOSITE UNITS CONTROL CIRCUITS. (2) lRlB CHANNEL 2 UNIT 1 CONTROL EQUIP ROOM RECORDEf1 CPM OVERHEAD ANNUNICIATOR * *I RELAYS L-l ___ ___, L---AUX I RELAYS _...,_ __ _... __ ___, L---CHANNEL l CHANNEL 2 115 PWR I
  • SUPPLY 1 MICROPROCESSOR ASSEMBLY CONTROL FUNCTIONS I INTERLOCKS [AS SHOWN IN TABLE 11.4.1(2)] CONTROL ROOM AREA SEE NOTE 1 VENTILATION ENTRY CONTROL ROOM AREA ENTRY DESIGNATED UNIT CHANNEL 1 DETECTOR 1 RlB SHOWN 2 RlB TYPICAL PSEG Nuclear, LLC OPPOSITE UNIT CHANNEL 2 DETECTOR Rev1s1on 21, Dec. 6, 2004 Salem -Nuclear Generating Station CONTROL AREA* INT f.J<E DUCT RADIATION MONITOR SALEM NUCLEAR GENERATING STATION Updated FSAR Figure 11.4-9