DISTRIBUTION:
NRC PDR t,lAY 3 0
i975 Local PDR'ocket ORB¹3 Rdg KRGoller TJCarter GLear CJDeBevec PDiBenedetto SATeets DRoss OELD OIGE (3)
ACRS (14)
Gray file extra cps (5)
It has been brought to our attention that General Electric has developed a new calculational method for determining void coefficients.
I Docket No. 50-220 Niagara Mohawk Power Corporation ATTN:
Mr. Gerald K. Rhode Yice President - Engineering 300 Erie Boulevard Nest
- Syracuse, New York 13202 Gentlemen:
The void coefficients are used in the transient analysis to determine the change of peak pressure and Minimum Critical Power Ratio limits associated with GETAB/GEXL Technical Specifications.
To maintain the required conservatism in transient analyses it will be necessary to use the void coefficient determined by the new calculational method.
Therefore, you are requested to inform the Nuclear Regulatory Commission, within 10 days from geceipt of this letter, as to how the new void coefficients will be accounted for in your forthcoming GETAB/GEXL submittal.
This request for generic information was approved by GAO under a blanket clearance number B-180225 (R0072); this clearance expires July 31, 1977.
Sincerely, (s/
George Lear, Chief Operating Reactors Branch ¹3 Division of Reactor Licensing cc:
See next page OPPIC4$
P'VQNAMSW ORB¹~3 CJDeBevec:km ORB¹ GLear +
o ATR $P,.5/~,...,./,7>
FOaa hEC-318 (RST. 9.$ $) hECM 0240 4 V, SI OOVERNMCNT PRINTINO OPPICKI IOTA 424 144
t A
0 Niagara Mohawk Power Corporation
~
g C
MAY q p
19TS.
CC:
Arvin E. Upton, Esquire
- LeBoeuf, Lamb, Leiby 5 MacRae 1757 N Street, N. N.
1'lashington, D. C.
20036 Anthony Z. Roisman, Esquire Berlin, Roisman 5 Kessler 1712 N Street, N. N.
l~lashington, D. C.
20036 Dr. William Seymour, Staff Coordinator New York State Atomic Energy Council New York State Department of Commerce 112 State Street
- Albany, New York 12207 Oswego City Library 120 E. Second Street Oswego,.
New York 13126