Letter Concerning the Review of Information Submitted Regarding the Mark I Containment Reevaluation Program and Requesting Additional Information Pertaining to the Functional Operability of Piping and Components When
ML17037C466
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 10/24/1975
From: Lear G
Office of Nuclear Reactor Regulation
To: Rhode G
Niagara Mohawk Power Corp
References
Download: ML17037C466 (6)


Text

Docket, No.

SO-220 Gentlemen:

DISTRIBUTION

NRC PDR 00T P 4 (975 Doc ORB¹3 Rdg KRGoller TJCarter GLear Niagara Mohawk Powor Corporation JGuibert ATTN:

Mr. Gerald K. Rhode CParrish Vice President - Engineering TBAbernathy 300 Erio Boulevard Nest SVarga

Syracuse, New York 13202 DEisenhut OELD 016E (3)

ACRS (16)

RE:

NINE MILE POINT UNIT 1 Gray file NPaulson Based on our review of tho information submitted on your docket regarding the Mark I containment reevaluation program (up to and including tho Mark I Containment Status Report dated, July 31, 1975,'ubmitted by tho Gonoral Electric Company),

we have idontified additional information that is required to continue our review.

The information required is listed in tho enclosure and pertains to tho functional operability of-piping and components when subjected to (1) pool swell loads associated with a loss-ol-coolant

accident, and (2) loads from operation of the primary system pressure relief valves.

The items listed in the enclosure should be addressed during the Long Term Program proposed by the Mark 1 (httners Group.

Ne anticipato that further information will be required based on our review of the Short Term Program report.

Please contact us if you desire clarification of tho information required.

This request for generic information was approved by GAO under a blanket clearance number B-180225 (R0072); this clearance expires July 31, 1977.

Sincerely, Z5/

George Lear, Chief Operating Reactors'ranch

¹3 Division of Reactor Licensing

Enclosure:

Request for Additional Information OFPICS~

SURNAMS~

OATS~

ORB¹ JGuibert:kmf 10/g3

/75 OR I

L 0/ y

/7S POnn AEC-318 (RCT. 9.f3) hECht 0240 Uo S OOVSRNMSNT PRINTINO OPPICSI IS74 S24 ISS

V 1

~

Niagara Mohawk Power Corporation

. CC:

Arvin E. Upton, Esquire

LeBoeuf, Lamb, Leiby 5 MacRae 17S7 N Street, N.

N.

Washington, D.

C.

20036 Anthony Z. Roisman, Esquire

Roisman, Kessler and Cashdan 1712 N Street, N.

Washington, D.

C.

20036 Dr. l(illiam Seymour, Staff Coordinator

. New York State Atomic Energy Council New York State Department of Commerce 112 State Street

Albany, New York 12207 Oswego City Library 120 E. Second Street

.Oswego,.

New York 13126 Mr. Robert P. Jones, Supervisor Town of Scriba R.

D.

Pi4 Oswego; New York 13126

EY,CLOSUfQi RE UEST FOI< ADDITIO'.iAL INFO'"LÃfIO!i 1.

Provide a list of piping and mechanical components which could be sub) "c".d to su l-" ass.'.on:>'Dol:ii'oti>.'.~

',! '. c s oa ~n'-; o"

$ o;:d> p'rs from operation of the prima.y system pressure relief valves; including dotailcd drawings and runctional description of such piping and components.

2.

Provide a description of methods and procedures used to define the pool clynamic loads and relief; alve actuation loads acting on the listed piping and components.

'3.

Provide a description of methods and procedu" s, either by <<nalysis or by testing, being used to ensure design adequacy of ti:e listed piping and components under pool dynamic loads or relief valve actuation loads.

S.

Provide a description rega 'ding how the pool dynamic loads 0

v live actuation loads being concurrently consid."red an<1 combin:d with other operation or accident loads acting o>> the listec! pipi.ng <<nd components.

Identify design limits used for the lis.ed piping and components un'lcr pool dynamic or relief valve actuation

!oa:!s.

IZ analysis or testing has been

done, a su "..ary oi analysis or test'i>>;, rcsul~;:

nnd ch~ir colilparison

~iith design 1 irllis s!.ou1-.!>>::;; ovided.

1.=.:~.".:!I"si s or testing 0::5 nest yet been done a 'sc'

)tion 'Qf [lie future pro~3 am to perform such testing or analysis should'c providecl.

~~. ~+,