th'ROMI
-, --Magara--i@hawk-Power Corporation
- Syracuse, Dew York 13202 IQRot H. Pistt ATEOF DOCUMENT DATE RECEIVED NO I g
h vs 4 20-70 0-20-70 LTR.
MEMO(
RE I
R h
- h. TOI ji.
ORIG.I CCI OTHERI Dr Peter A. Norris.
ACTION NKCKSSARY Q
VO ACTION NKCKSSARY Q CONCURRENCE Q
DATE ANSWERED COMMENT BYi CLASSIFI POST OFFICE EG. NOI U
R DEscRIpTIoNI (Must Be Unclsss fied)
FILE CODEI p 22p (3lFUT)(2)
DATE REFERRED TO RECEIVED BY DATE Ltr trans the followingt req for Andt to Lic. DPR-17 5, Chge to Tech Specs.
Ziemann w
c s for act
-21 7 n
ENCLOSURES Petitionp notarized 4-16-70 entitled "Petition Requesting Anendment of License." (3 prig signed 8o 25 conf'd, "Technical Supplement to Petition to Increase Power level." (70 cys)
DISXRIBUTIPH:
Regulatory fi AEC PDR Compliance (2)
PaC Rn P O6 H. Price h S D be Skovho t D. Thompson DO NOT REMO E REMARKSI DeYoung DTIt"(Laughlin) mSXC(Buchanan)
DWIIXOKI 13.8v
- fod,
- U. ~. OOYRRNNNNT RRINTINO ORRICR< 84tWIS Us. ATDMIC ENERGY ooMMISSIDN MAIL CpwyRpL FpRM FoRM AEc-9268 IS-co)
t.
l
~
~
j~
~'"'P (5
4t
'~.~
~.N iJ'
~,5 g
l I
gg
NIAGARA MOHAWK POWER CORPORATION NIAGARA~
MOHAWK 300 ERIE BOULEVARD WEST SYRACUSE, N.Y, I3202 April 20, 1970 Dr. Peter A. Morris Director Division of Reactor Licensing U. S.. Atomic Energy Commission Washington, D. C. 20545
Dear Dr. Morris:
Re:
Niagara Mohawk Power Corporation Docket No.
5 0-220 regulatory a
Niagara Mohawk Power Corporation hereby transmits three (3) originals and twenty-five (25) copies of a petition entitled, "Petition Requesting Amendment of License; " Accompanyin'g this petition and incorporated in it by reference are'seventy (70) copies of a document entitled, "Technical Supplement to Petition to Increase Power Level."
File Cy, Service of this petition and its accompanying supplement willbe made upon the appropriate local officials. After such service is made, a Certificate of Service willbe sent to you.
Very truly yours, Niagara Mohawk Power Corporation By.
Mint.P t
Vice President and Executive Engineer Enclo sur e s ll.
QSIIEC P820 iS7ag =
REGUUITORy g
MAlL SECT(Og 4 r
DOCKET CLEII gf ])~4 1 < ~Q
!.183
" 3H' I ~
1 gP
UNITED STATES OF AMERICA vATOMIC ENERQP COMMISSION, Regulator File Cy.
In the Matter of
)
Niagara Mohawk Power Corporation
)
Rscssvsd vvicsv Ddt~+ Mcc-Wdd Docket No. 50-220 Petition Requesting Amendment of License Niagara Mohawk Power Corporation, Licensee in the above-captioned proceeding, hereby files its petition to amend its license in order to allow operation of its Nine Mile Point facility at a higher power level than the present license permits.
In support of this petition, Licensee states as follows:
(1)
Licensee received on August 22,
- 1969, a
provisional operating license (DPR-17) permitting it to operate its Nine Mile gl A i Point facility at 1538 MWt.
(2)
At the time of the design and construction of the aforementioned facility, Niagara Mohawk had the components of the facility designed to accommodate operation of the facility at a power level higher than the power level presently authorized.
In addition, the principal
>>2-postulated accidents for the facility were also analyzed at a power level considerably higher than the power level presently authorized.
(3)
A document entitled, "Technical Supplement to Petition to Increase Power Level" accompanies this petition and is hereby incorpor ated by referenc e.
This Supplement contains:
(a) a description of minor changes to the facility, none of which reflects upon the capability of the facility; (b) a reanalysis of postulated accidents at the higher power level; (c) proposed revised technical specifications; (d) a summary of the initial startup of the facility, and (e) other relevant technical material.
WHEREFORE, Licensee prays that its operating license
0 be amended to allow operation of its Nine Mile Point facility at 1850 Mwt.
NIAGARAMOHAWKPOWER CORPORATION inot
. Pratt Vice President and Executive Engineer Subscribed and sworn to before me this day of 1970 Notary Publi HELEN A. NAPOLI Note+ PublIc In the Stete ol Itew Yeti Quelltlcd ln onon. co, Ilo. 34.II097225 atty Contntleelon Expltes Match 30, 19~
'1
~,
I I
l'J E