NRC FORM 195 (2.76)

TO:

NRC, QLETTER

@ORIGINAL Q COP Y 0 NOTOR IZ6 D g UNC LASS IF I E D FROM:

PROP Niagara Moha~7k Power Corp.

t

Syracuse, NY 13202 R. R. Schnhi er

/

INPUT FORM t

U.S. NUCLEAR REGULATORY C ISSION l'RC DISTRIBUTION FQR PART 50 DOCKET MATERIAL, DOCKET NUMBER 50-220 FILE NUMBER MONTHLY REPORT DATE OF DOCUMENT

2/2/77 DATE RECEIVED 2/8/77 NUMBER OF COPIES RECEIVED 1 Cy DESCRIPTION LETTER TRANS THE FOLLOWING:

ENCLOSU RE MONTHLY REPORT FOR Januar 197 PLANT & COMPONENT OPERABILITY &

AVAILABILITY, THIS REPORT TO BE USED IN PREPARING GRAY BOOK BY PLANS &

OPERATIONS'ine Mile Point Unit 1

( 0 I ~,PL)

ACgyp~

DGgg)

DP >PT REMOVE X

MIPC CYS FOR AC ON FOR ACTION/INFORMATION INTERNALDISTRIBUTION PDR

-BRANCH CHIEF L arrish EXTERNALDISTRIBUTION CONTROL NUMBE R 1360 NRC FORM 196 I2.76)

'k

'll

,t g+ ~

J\\

NIAGARAMOHAWKPOWER CORPORATION NIAGARA ~

MOHAWK 300 ERIE BOULEVARD. WEST SYRACUSE. N. Y. I3202 R'egutatory Docket FiIi Feb~y 2, 1977 0(gce, o$ Plane 8 Schedule V~mto~e, of Licerukng Unkted ~u Nuef~ Regulatory CommQ ak on olaehingkon, V.C.

20555

.RE:

'Dock& No. 50-220 GmtLemen:

FEBS )yy.

i

.~~ RHGUMQAE Sub~ed hneuMh. ~ Che, Oping S~

RepoM Joe She, moeth o$ 3anuaIIIJ 1977 Joe Che,, N~ne KQ!e, Po~ Nues~

PouIW S~on Unit'l.

Very ~y you@6, R.R. SckmufeII, VL ce PauM~-

Efmtru,c Paodu~on (fAS/atm

~chme~

APPENDIX C OPERATING DATA REPORT DOCKET NO 50-220 UN)T Nine Ni 1 e P

DATE 02/03/77 COMPLETED BY T.J.

er ins TEI EPHONE 315 343-OPERATING STATUS.

1. REPORTING PERIOD: 770101 770131 GROSS HOURS IN REPORTING PERIOD:

744

2. CURRENTLY AUTHORIZEDPOWER LEVEL(MIN:

5 MAX.DEPEND. CAPACITY (MWe Nei):

DESIGN ELECTRICALRATING (bIWe.Net):

3. POWER LEVEL TO WHICH RESTRICTED (IF ANY) (MWe.Net):
4. REASONS FOR RESTRICTION (IF ANY):

610

6. NUMBER OF HOURS REACTOR WAS CRITICAL
6. REACTOR RESERVE SHUTDOWN HOURS THIS MONTH 744 YR TO DATE 744 CUMULATIVE 46,469.4 1,188.0
7. HOURS GENERATOR ON LINE
8. UNITRESERVE SIIUTDOWN HOURS
9. GROSS THERMALENERGY GFNERATED (MWH)
10. GROSS ELECTRICAL ENERGY GENERATED (MiWH) 11 NET ELECTRICAL ENERGY GENERATED (MWH)
12. REACTOR SLRVICE FACTOR
13. REACTOR AVAILABILITYFACTOR
14. UNITSERVICE FACTOR,
16. UNITAVAILABILITYFACTOR
16. UNIT CAPACITY FACTOR (Using MDC)
17. UNIT CAPACITY FACTOR (Using Design 0/IWc)
16. UNIT FORCED OUTAGE RATE 744 1338 810 442,689 428,572 100 100 100 94.4 94 '

428,572 100 100 100 94.4 94.4 22,459,493 75:0 69.6 57.9 5P.9 12.4 744 44,250.8 20.2 1

338 810 70 640 317 442,689 23,180,744

19. SHUTDOWNS SCHEDULED OVER NEXT 6 MiONTHS (TYPE, DATE, AND DURATION OF EACH):

REFUELING -'March 6, 1977 - 12 wee's

20. IF SHUT DOWN AT END OF REPORT PERIOD. ESTIMATED DATE OF STARTUP:
21. UNITS IN TEST STATUS (PRIOR TO COMMERCIALOPF RATION):

FORFCAST ACHIEVED INITIALCRITICALITY INITIALELECTRICITY COMMERCIALOPERATION

NINE >1ILE PODilT NUCLEAR STATION

. NT.AG 'OHKRX POt'ER CORPORAT.TO l AVERAGE DAILYUbllT PO)VER LEYEL DOCKET"NO.

50-220 Nine Mi1e Point 81 DATE 02/03/77 COMPLETED BY TELEPHONE T.J.'erkins (315) 343-2110 ext.

1312

~ fOXTrI Januar 1977 DAY AVERAGEDAILYPOWER LEVEL

(~I)Ye-X~'et) 1 580.9 584.4 DAY AVERAGEDAILYPONER LFVEL PI%'e-N e t) 578.0 576.8 582. 7 19 582.1 577.0 574.7 572.8 523.5 20 583. 5 23

. 584.4 582.0 10 13 578.7 582.5 581.1 583.4 582.1 584.5 581.8

'S 27 30 31 58 581.8.

581. 9 581.6 578.2 574.7

NINP. MILE POINT NUCLEAR STATION NIAGARA MOHAMK POWER CORPORATION UN(T SHUTDOWNS AND POWER REDUCT)ONS P

@EPOPT MOgT[-(

DOCKET NO.

50-220 Nine Nile Point 81 DATE COMPLETED BY TELEPpOgp (315)343-2110 ext.

1312 NO.

DATE TYPE F: FORCED DURATION S: SCHEDULED (HOURS)

REASON (1)

METHOD OF SHUTTING DOmtN THE REACTOR OR REDUCING POWER (2)

COB R ECTIVE ACTIONS/COMMENTS (I)

REASON h: Eoulf MEvrFAILURE(Exr LAIN)

II: MAINT.OR TEST C: REFUELING

. D: REGULhTORY RESTRICrION L: OPERATOR TRAININGAND LICENSE EXAMINATION Pl ADMINISI'RATIVE G; Ol'LRATlONAf.ERROR (EXPLAIN)

H: OTHER (EXPLAIN)

(2)

METHOD I: MANUAL 2: MANUALSCRhibf.

3: AUTOMATICSCRAM 4; OTIIEI<<ExfLAIN)

SEIMARY:

~

~

h>>