1 NRR-PMDAPEm Resource From:
Rankin, Jennivine Sent:
Monday, January 09, 2017 10:52 AM To:
ERICKSON, JEFFREY S (JERICKS@entergy.com); MIKSA, JAMES P (jmiksa@entergy.com)
Subject:
Palisades Nuclear Plant - Acceptance Review of Limited Coverage Examinations During the Fourth 10-year ISI Relief Request (MF8886)
Mr. Miksa and Mr. Erickson, By letter dated November 30, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16335A032), Entergy Nuclear Operations, Inc. (the licensee), submitted a relief request for Palisades Nuclear Plant (PNP). The proposed relief requests U.S. Nuclear Regulatory Commission (NRC) authorization for limited coverage examinations during the fourth 10-year inservice inspection interval.
The purpose of this e-mail is to provide the results of the NRC staffs acceptance review of this relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
Consistent with Section 50.55a(g)(5)(iii) of Title 10 of the Code of Federal Regulations, the applicant may submit to the NRC a determination of impracticality based on the demonstrated limitations experienced when attempting to comply with the Code requirements during the inservice inspection interval for which the request is being submitted.
The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed relief request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.
Based on the information provided in your submittal, the NRC staff has estimated that this licensing request will take approximately 240 hours0.00278 days <br />0.0667 hours <br />3.968254e-4 weeks <br />9.132e-5 months <br /> to complete. The NRC staff expects to complete this review in approximately 9 months, which is August 2017. If there are emergent complexities or challenges in our review that would cause changes to the initial forecasted completion date (greater than a month) or significant changes in the forecasted hours (greater than 25%), I will communicate the reasons for the changes, along with the new estimates during our routine interactions. These estimates are based on the staffs initial review of the application and they could change, due to several factors including requests for additional information and unanticipated addition of scope to the review.
If you have any questions, please contact me at (301) 415-1530.
- Thanks, Jennie Jennie Rankin, Project Manager Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
Hearing Identifier:
NRR_PMDA Email Number:
3255 Mail Envelope Properties (Jennivine.Rankin@nrc.gov20170109105200)
Subject:
Palisades Nuclear Plant - Acceptance Review of Limited Coverage Examinations During the Fourth 10-year ISI Relief Request (MF8886)
Sent Date:
1/9/2017 10:52:16 AM Received Date:
1/9/2017 10:52:00 AM From:
Rankin, Jennivine Created By:
Jennivine.Rankin@nrc.gov Recipients:
"ERICKSON, JEFFREY S (JERICKS@entergy.com)" <JERICKS@entergy.com>
Tracking Status: None "MIKSA, JAMES P (jmiksa@entergy.com)" <jmiksa@entergy.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 3079 1/9/2017 10:52:00 AM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: