AMERICAN ELECTRIC POWER COOK NUCLAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.1-8

Title:

D.C. Cook Unit 2 Heat Removal by Lower Compartment Spray Change

Description:

UCR-1974, Rev. 0 Sheet 1 of 1 Revision: 24.0 Notes:

1. Due to errors identified with the LOTIC2 containment backpressure calculation, an evaluation was performed assuming a revised initial CTS temperature. See Section 14.3.1.5 for more information.