IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

18.1 Table: 14.1.6-2 Page:

1 of 1 UNIT 2 TIME SEQUENCE OF EVENTS Accident Event Time (sec)

Single Reactor Coolant Pump Locked Rotor Four loops in operation, one locked rotor Rotor in one pump locks 0.00 Low reactor coolant flow trip setpoint reached 0.02 Rods begin to drop 1.02 Time at which minimum DNBR is predicted to occur 2.2 Maximum RCS pressure occurs 3.10 Maximum clad temperature occurs 3.60