ML16343A772
| ML16343A772 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 10/24/2016 |
| From: | Indiana Michigan Power Co |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML16336A263 | List:
|
| References | |
| AEP-NRC-2016-42 | |
| Download: ML16343A772 (1) | |
Text
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
22 Table: 14.3.9-23 Page:
1 of 1 UNIT 1 BOUNDING DEBRIS AT REMOTE STRAINER FOR SACRIFICIAL STRAINER AREA CONSIDERATION FOR DEGB AND DGBS Debris Type Debris Generated Transport Fraction Debris at Strainer Electromark Labels (inside ZOI), ft2 0.7 0.47 0.329 Electromark Labels (outside ZOI), ft2 39.6 0.69 27.324 Unqualified Labels (all of containment), ft2 25.94 0.4 10.38 Fire Barrier Tape Small Pieces (< 4 in), ft2 14.4 0
0 Fire Barrier Tape Large Pieces ( 4 in), ft2 54.1 0
0 Flexible Conduit PVC Jacketing, ft2 1.57 0.3 0.471 Ice Storage Bag Liner Shards, ft2 0.87 0.42 0.365 Pieces of Work Platform Rubber, ft2 0.22 0.42 0.092 Total, ft2 137.4 38.96