IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

22 Table: 14.3.9-22 Page:

1 of 1 UNIT 1 BOUNDING DEBRIS AT MAIN STRAINER FOR SACRIFICIAL STRAINER AREA CONSIDERATION FOR DEGB AND DGBS Debris Type Debris Generated Transport Fraction Debris at Strainer Electromark Labels (inside ZOI), ft2 0.7 0.13 0.091 Electromark Labels (outside ZOI), ft2 39.6 0.03 1.188 Unqualified Labels (all of containment), ft2 25.94 0.86 22.308 Fire Barrier Tape Small Pieces (< 4 in), ft2 14.4 0.13 1.872 Fire Barrier Tape Large Pieces ( 4 in), ft2 54.1 0.13 7.033 Flexible Conduit PVC Jacketing, ft2 1.57 1