ML16343A761

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 14, Table 14.3.9-14, Debris Quantities for Mftl Head Loss Tests
ML16343A761
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A761 (1)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

22 Table: 14.3.9-14 Page:

1 of 1 UNIT 1 DEBRIS QUANTITIES FOR MFTL HEAD LOSS TESTS Debris Type Units Mass Test 1 (DEGB)

Mass Test 2 (DGBS)