IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

22 Table: 14.3.9-8 Page:

1 of 1 UNIT 1 CONTAINMENT MATERIALS Submerged Aluminum Metal (Below El. 614 ft)

Mass, lb Area, ft2 Electrical Equipment (Limit Switches) 1.5 0.44 Fans and Motors 2.31 3.67 Radiation Detectors 0.72 0.36 Miscellaneous Components 17.72 6.46 NSSS Components (NRI-32,-36,-41A thru -44B) - Located in Reactor Cavity 244.00 83.00 TOTAL - Including Components in Reactor Cavity 266.25 93.93 TOTAL - Excluding NSSS Components in Reactor Cavity 22.25 10.93 Non-submerged Aluminum Metal (Above El. 614 ft)

Mass, lb Area, ft2 Electrical Equipment 0.80 0.81 Radiation Detectors 0.03 0.06 Valve Components 8.00 2.47 Crane Components 1.05 0.72 Miscellaneous Components 22.97 9.33 NSSS Components (RCP Cooling Coils) 1,152.00 8,000.00 TOTAL 1,184.85 8,013.39 Uncoated Concrete (Exposed Concrete)

Area, ft2 Submerged (Below El. 614 ft) 6,412.78 Non-submerged (Above El. 614 ft) 1,077.10 Zinc Coated Steel (Below El. 614 ft)

Area, ft2 Galvanized Steel (Below El. 614 ft) 70,831.64 Cold Zinc Coated Steel (Below El. 614 ft) 330.98 Total submerged zinc coated steel 71,162.62 Zinc Coated Steel (Above 614 ft)

Area, ft2 Galvanized Steel (Above El. 614 ft) 495,734.96 Cold Zinc Coated Steel (Above El. 614 ft) 8994.00 Total non-submerged zinc coated steel 504,728.96