IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
22 Table: 14.3.9-5 Page:
1 of 1 UNIT 1 DGBS COATINGS DEBRIS GENERATED WITHIN ZOI Coating Type Area, ft2 Thickness, mils Volume, ft3 Density, lbs/ft3 Weight, lbs Qualified Coatings - Concrete Surfaces (ZOI - 5D) 0 12 0.0 111.6 0.0 Qualified Coatings - Steel Surfaces (ZOI - 5D) 20 12 0.02 111.6 2.2 Total Qualified (ZOI - 5D) 20 0.02 2.2 Unqualified Alkyd Coatings (ZOI - 10D) 16.9 4
0.006 98 0.6 Unqualified Epoxy Coatings (ZOI - 10D) 56.0 4
0.019 94 1.8 Total Unqualified (ZOI - 10D) 72.9 0.025 2.4