IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
22 Table: 14.3.9-4 Page:
1 of 1 UNIT 1 DEGB COATINGS DEBRIS GENERATED WITHIN ZOI Coating Type Area, ft2 Thickness, mils Volume, ft3 Density, lbs/ft3 Weight, lbs Qualified Coatings - Concrete Surfaces (ZOI - 5D) 894 12 0.894 111.6 99.8 Qualified Coatings - Steel Surfaces (ZOI - 5D) 1,007 12 1.007 111.6 112.7 Total Qualified (ZOI - 5D) 1,901 1.90 212.5 Unqualified Alkyd Coatings (ZOI - 10D) 57.7 4
0.019 98 1.9 Unqualified Epoxy Coatings (ZOI - 10D) 112.0 4
0.037 94 3.5 Total Unqualified (ZOI - 10D) 169.7 0.056 5.4