1 of 1 Unit 1 PARAMETERS USED IN BOUNDING STEAMLINE BREAK MASS / ENERGY RELEASES FOR UNIT 1 AND UNIT 2 Parameter Parameter Value NSSS Power, MWt 3608 Core Power, MWt 3588 RCS Flow, gpm/loop 79000 Minimum Measured Flow, gpm/loop 91600 Core Outlet Temperature, °F 618.0 Vessel Outlet Temperature, °F 615.2 Vessel Average Temperature, °F 581.3 Vessel/Core Inlet Temperature, °F 547.4 Steam Generator Outlet Temperature, °F 547.1 Zero Load Temperature, °F 547.0 RCS Pressure, psia 2250 or 2100 Steam Pressure, psia 858.2 Steam Flow (10 6 lb/hr total) 16.00 Feedwater Temp., °F 449.0 SG Tube Plugging, %