ML16343A727

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 14, Table 14.3.4-38, Peak Pressures/Differentials
ML16343A727
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A727 (1)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17.1 Table: 14.3.4-38 Page:

1 of 1 Unit 1 PEAK PRESSURES / DIFFERENTIALS DEHL Break In Element #6 DECL Break In Element #6 Pressure In Element #6 (Psig) 14.8 / 14.4 13.4 / 13.0 Peak Pressure In Ice Condenser Compartments (Psig) 10.6 / 10.6 9.8 / 9.9 Peak Differential Pressure Across Operating Deck or Lower Crane Wall (Psi) 14.5 / 14.1 12.3 / 11.7