Text
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17.1 Table: 14.3.4-37 Page:
1 of 1 Unit 1 1973 WALTZ MILL PRELIMINARY TEST CONDITIONS Nominal Conditions Test Series Gtest/
Gplant (Total Energy/Ice Wt.) test/
(Total Energy/Ice Wt.) plant Subcooling In Piping Varied in Test Setup Blowdown rate Series 37%
75%
100%
150%
10%
1.5%
100%
40oF Variable Orifice Sizes Blowdown Energy Series 75%
100%
100%
150%
150%
200%
~40oF Variable Boiler Water levels Blowdown Transient Shape Series 75%
75%
100%
100%
100%
~10oF
~25oF
~10oF
~25oF Variable Conditions In Subcooled Leg