ML16343A725
| ML16343A725 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 10/24/2016 |
| From: | Indiana Michigan Power Co |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML16336A263 | List:
|
| References | |
| AEP-NRC-2016-42 | |
| Download: ML16343A725 (2) | |
Text
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17.1 Table: 14.3.4-36 Page:
1 of 2 Unit 1 SENSITIVITY STUDIES FOR COOK NUCLEAR PLANT Parameter Change Made From Base Value Change In Operating Deck Dp Change In Peak Pressure Against The Shell Blowdown
+10%
+11%
+12%
Blowdown
-10%
-10%
-12%
Blowdown
-20%
-20%
-23%
Blowdown
-50%
-50%
-53%
Break Compartment Inertial Length
+10%
+4%
+1%
Break Compartment Inertial Length
-10%
-4%
-1%
Break Compartment Volume
+10%
-2%
-1%
Break Compartment Volume
-10%
+2%
+1%
Break Compartment Vent Areas
+10%
-6%
-5%
Break Compartment Vent Areas
-10%
+8%
+5%
Door Port Failure in Break Compartment one door port fails to open
+1%
-1%
Ice Mass
+10%
0 0
Ice Mass
-10%
0 0
Door Inertia
+10%
+1%
0 Door Inertia
-10%
-1%
0 All Inertial Lengths
+10%
+5%
+4%
All Inertial Lengths
-10%
-5%
-3%
Ice Bed Loss Coefficients
+10%
0 0
Ice Bed Loss Coefficients
- 10%
0 0
Entrainment Level 0% Ent
-27%
-11%
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17.1 Table: 14.3.4-36 Page:
2 of 2 Unit 1 SENSITIVITY STUDIES FOR COOK NUCLEAR PLANT Parameter Change Made From Base Value Change In Operating Deck Dp Change In Peak Pressure Against The Shell Entrainment Level 30% Ent.
-19%
-15%
Entrainment Level 50% Ent.
-13%
-12%
Entrainment Level 75% Ent.
-6%
-6%
Lower Compartment Loss Coefficients
+10%
0 0
Lower Compartment Loss Coefficients
-10%
0 0
Cross Flow in Lower Plenum Low estimate of resistance 0
-7%
Cross Flow in Lower Plenum High estimate of resistance 0
-3%
Ice Condenser Flow Area
+10%
0
-3%
Ice Condenser Flow Area
-10%
0
+4%
Ice Condenser
+20%
0
-6%
Ice Condenser Flow Area
-50%
0
+8%
Initial Pressure in Containment
+0.3 psi
+2%
+2%
Initial Pressure in Containment
-0.3 psi
-2%
-2%
Reactor Coolant Break Enthalpy
-13.0%
+6%
+3%
Compressibility Factor Addition of the compressibility factor
+4%
0 All values shown are to the nearest percent.