IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17.1 Table: 14.3.4-35 Page:

1 of 1 Unit 1 ICE CONDENSER AZIMUTHAL DIFFERENTIAL PRESSURE DISTRIBUTION TMD BREAK LOCATION ELEMENTS 1

2 3

4 5

6 Ice Condenser Bays 1 thru 2.75 Bays 2.75 thru 6 Bays 7 thru 12.5 Bays 12.5 thru 17 Bays 18 thru 20.5 Bays 20.5 thru 24 Elements 9

12 15 18 21 24 Pressure 7.4 psid 6.1 psid 5.5 psid 5.5 psid 6.1 psid 7.4 psid Elements 8

11 14 17 20 23 Pressure 9.2 psid 7.6 psid 6.8 psid 6.8 psid 7.5 psid 9.2 psid Elements 7

10 13 16 19 22 Pressure 11.8 psid 9.8 psid 8.7 psid 8.7 psid 9.7 psid 11.8 psid Elements 40 41 42 43 44 45 Pressure 14.8 psid 12.6 psid 11.2 psid 11.2 psid 12.4 psid 14.5 psid