IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
19.3 Table: 14.3.4-33 Page:
1 of 1 UNIT 1 PEAK DIFFERENTIAL PRESSURE (PSI)
STEAM LINE BREAK AT OUTLET NOZZLE (BOUNDING)1 Limiting Containment Conditions Across Structures:
DP55-25=42.7691 PSI 1.210 SEC THigh/PLow DP56-25=31.1990 PSI 1.297 SEC THigh/PLow DP57-25=31.1953 PSI 1.296 SEC THigh/PLow DP58-25=31.5021 PSI 1.291 SEC THigh/PLow DP59-25=31.5003 PSI 1.292 SEC THigh/PLow DP60-25=19.3257 PSI 1.344 SEC THigh/PLow DP61-25=19.1868 PSI 1.346 SEC THigh/PLow DP62-25=19.1902 PSI 1.342 SEC THigh/PLow DP63-25=19.3621 PSI 1.340 SEC THigh/PLow DP55-46=25.7593 PSI
.017 SEC TLow/PLow DP56-47=13.7783 PSI
.022 SEC TLow/PLow DP57-48=12.1139 PSI
.034 SEC TLow/PLow DP60-51=11.0594 PSI
.038 SEC TLow/PLow DP61-52=10.0894 PSI
.041 SEC TLow/PLow Across Steam Generator Vessel:
DP56-58=-2.8489 PSI
.024 SEC TLow/PLow DP57-59=-3.9901 PSI
.023 SEC TLow/PLow Node 46 Break DP60-62=2.6747 PSI
.041 SEC TLow/PLow DP61-63=-1.9412 PSI
.030 SEC TLow/PLow Node 46 Break 1 All breaks are in Node 55 unless otherwise noted.