ML16343A633

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 14, Table 14.3.4-24, Loop Subcompartment Model - Tmd Volume Input
ML16343A633
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A633 (3)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17.1 Table: 14.3.4-24 Page:

1 of 3 Unit 1 TABLE 14.3.4-24 LOOP SUBCOMPARTMENT MODEL - TMD VOLUME INPUT TMD Node Description Volume (ft3)

TMD Node Unique to this Model TMD Node Common to Pressurizer Enclosure &

Steam Generator Enclosure Models 1

Loop Compartment 2.2415E+04 No Yes 2

Loop Compartment 2.2845E+04 No Yes 3

Loop Compartment 4.1329E+04 No Yes 4

Loop Compartment 2.7398E+04 No Yes 5

Loop Compartment 2.2839E+04 No Yes 6

Loop Compartment 1.9921E+04 No Yes 7

Ice Condenser 3.5230E+03 No Yes 8

Ice Condenser 3.5230E+03 No Yes 9

Ice Condenser 3.4090E+03 No Yes 10 Ice Condenser 4.1660E+03 No Yes 11 Ice Condenser 4.1660E+03 No Yes 12 Ice Condenser 4.0330E+03 No Yes 13 Ice Condenser 8.3300E+03 No Yes 14 Ice Condenser 8.3300E+03 No Yes 15 Ice Condenser 8.0590E+03 No Yes 16 Ice Condenser 5.7680E+03 No Yes 17 Ice Condenser 5.7680E+03 No Yes 18 Ice Condenser 5.5800E+03 No Yes 19 Ice Condenser 4.4850E+03 No Yes 20 Ice Condenser 4.4850E+03 No Yes 21 Ice Condenser 4.3400E+03 No Yes

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17.1 Table: 14.3.4-24 Page:

2 of 3 Unit 1 TABLE 14.3.4-24 LOOP SUBCOMPARTMENT MODEL - TMD VOLUME INPUT TMD Node Description Volume (ft3)

TMD Node Unique to this Model TMD Node Common to Pressurizer Enclosure &

Steam Generator Enclosure Models 22 Ice Condenser 4.4850E+03 No Yes 23 Ice Condenser 4.4850E+03 No Yes 24 Ice Condenser 4.3400E+03 No Yes 25 Upper Containment 7.3432E+05 No Yes 26 Pipe Trench 1.0435E+04 No Yes 27 Fan/Accumulator Room 2.6969E+04 No Yes 28 Pipe Trench 1.0435E+04 No Yes 29 Instrument Room 1.7479E+04 No Yes 30 Pipe Trench 1.0435E+04 No Yes 31 Fan/Accumulator Room 2.6969E+04 No Yes 32 Pipe Trench 1.0435E+04 No Yes 33 Upper Reactor Cavity 1.8012E+04 No Yes 34 Ice Condenser 5.3850E+03 No Yes 35 Ice Condenser 6.3650E+03 No Yes 36 Ice Condenser 1.2729E+04 No Yes 37 Ice Condenser 8.8130E+03 No Yes 38 Ice Condenser 6.8540E+03 No Yes 39 Ice Condenser 6.8540E+03 No Yes 40 Ice Condenser 2.8910E+03 No Yes 41 Ice Condenser 3.4180E+03 No Yes 42 Ice Condenser 6.8350E+03 No Yes

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17.1 Table: 14.3.4-24 Page:

3 of 3 Unit 1 TABLE 14.3.4-24 LOOP SUBCOMPARTMENT MODEL - TMD VOLUME INPUT TMD Node Description Volume (ft3)

TMD Node Unique to this Model TMD Node Common to Pressurizer Enclosure &

Steam Generator Enclosure Models 43 Ice Condenser 4.7320E+03 No Yes 44 Ice Condenser 3.6810E+03 No Yes 45 Ice Condenser 3.6810E+03 No Yes 46 Steam Generator Enclosure 3.4040E+03 Yes No 47 Steam Generator Enclosure 3.1210E+03 Yes No 48 Steam Generator Enclosure 3.1210E+03 Yes No 49 Steam Generator Enclosure 3.4040E+03 Yes No 50 Steam Generator Enclosure 7.5010E+03 Yes No 51 Steam Generator Enclosure 6.9860E+03 Yes No 52 Steam Generator Enclosure 6.9860E+03 Yes No 53 Steam Generator Enclosure 7.5010E+03 Yes No