Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17.1 Table: 14.3.4-18 Page:

1 of 2 Unit 1 TABLE 14.3.4-18 DOUBLE-ENDED HOT LEG BREAK MASS AND ENERGY RELEASES Time (sec)

Mass (lb/sec)

Energy (BTU/sec) 0.00000 0.000000+4 0.000000+6 0.00201 6.296400+4 3.616100+7 0.00401 7.377000+4 4.235700+7 0.00900 6.916800+4 3.973700+7 0.01200 7.047200+4 4.051200+7 0.01602 7.176400+4 4.127400+7 0.01800 7.220100+4 4.153500+7 0.02500 7.467100+4 4.308700+7 0.02600 9.129400+4 5.264000+7 0.03000 9.888800+4 5.705000+7 0.03100 9.359200+4 5.392400+7 0.03300 1.034800+5 5.976200+7 0.04100 9.387700+4 5.419200+7 0.04301 9.958000+4 5.748900+7 0.04500 9.310800+4 5.373800+7 0.04900 1.018200+5 5.884600+7 0.05300 9.121800+4 5.262800+7 0.05401 1.044100+5 6.038900+7 0.05501 9.202900+4 5.320000+7 0.05800 9.912800+4 5.729100+7 0.06000 9.173100+4 5.296500+7 0.06301 9.862900+4 5.702600+7 0.06400 9.010400+4 5.204400+7 0.06500 9.892900+4 5.723900+7 0.06701 9.587100+4 5.549400+7 0.06801 1.003200+5 5.805800+7

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17.1 Table: 14.3.4-18 Page:

2 of 2 Unit 1 TABLE 14.3.4-18 DOUBLE-ENDED HOT LEG BREAK MASS AND ENERGY RELEASES Time (sec)

Mass (lb/sec)

Energy (BTU/sec) 0.07101 9.013600+4 5.208200+7 0.07200 9.396300+4 5.452900+7 0.07501 8.496600+4 4.913900+7 0.07600 9.286800+4 5.381600+7 0.08000 9.345900+4 5.411400+7 0.08301 9.631400+4 5.578500+7 0.08900 9.182300+4 5.321800+7 0.09401 8.716100+4 5.049300+7 0.10002 8.686700+4 5.036900+7 0.10103 8.751800+4 5.074300+7 0.10702 8.667200+4 5.026600+7 0.11702 8.066200+4 4.679300+7 0.12400 7.836000+4 4.550000+7 0.13004 7.823800+4 4.547300+7 0.19005 6.766600+4 3.960300+7 0.40013 6.328000+4 3.674300+7 0.60020 6.005400+4 3.460400+7 1.00020 5.560800+4 3.192700+7 1.52020 5.046300+4 2.929200+7 2.00020 4.687700+4 2.759500+7 3.00000 4.687700+4 2.759500+7