Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17.1 Table: 14.3.4-17 Page:

1 of 2 Unit 1 FAN ROOM - BACKFLOW CONTRIBUTION Time (sec)

Mass Flow Rate 103 lb/sec Energy Flow Rate 106 BTU/sec 0

7.54 8.99

.1 4.68 5.58

.2 4.48 5.34

.3 4.41 5.26

.4 4.32 5.15

.5 4.27 5.09

.6 4.15 4.95

.7 3.93 4.68

.8 3.59 4.28

.9 3.62 4.32 1.0 3.53 4.21 1.5 3.17 3.78 2.0 3.00 3.58 2.5 2.93 3.49 3.0 2.87 3.42 3.5 2.87 3.42 4.0 2.83 3.37 4.5 2.79 3.33 5.0 2.81 3.35 5.5 2.77 3.30 6.0 2.72 3.24 6.5 2.72 3.24 7.0 2.69 3.21 8.0 2.65 3.16 8.5 2.65 3.16 9.0 2.65 3.16 9.5 2.65 3.16 10.0 2.65 3.16 With 1.4 ft2 orifice in cross-connect to steam dump header; break in longest line.

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17.1 Table: 14.3.4-17 Page:

2 of 2 Unit 1 FAN ROOM - FORWARD FLOW CONTRIBUTION Time (sec)

Mass Flow Rate 103 lb/sec Energy Flow Rate 106 BTU/sec 0

5.55 6.62

.1 4.15 4.94

.2 3.05 3.64

.4 2.95 3.52

.6 2.90 3.46

.8 2.78 3.31 1.0 2.75 3.28 1.5 2.67 3.19 2.0 3.45 3.38 2.5 9.50 5.26 3.0 9.42 5.21 3.5 9.38 5.19 4.0 9.33 5.16 4.5 9.28 5.13 5.0 9.23 5.10 5.5 9.16 5.07 6.0 9.10 5.04 6.5 9.03 5.01 7.0 8.95 4.97 7.5 8.86 4.93 8.0 8.80 4.91 8.5 8.70 4.86 9.0 8.58 4.81 9.5 8.46 4.76 10.0 8.33 4.70