IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

16.1 Table: 14.3.4-14 Page:

1 of 1 KEY PARAMETERS AFFECTING SPLIT STEAM LINE BREAKS Variable Values Used In LOTIC-3 Report Values for D. C. Cook Full Load Steam Pressure (psia) 1000 820 Plant Power (Mwt) 3425 3403 Time Delay to Feedline Isolation (sec) 15 9.0 Time Delay to Steam Line Isolation (sec) 15 9.0